background image

En-5

(2)  Remote controller DIP switch 1 setting

 Set the remote controller DIP switch 1-No. 2 according to the following 
table.

Number of remote 

controllers

Master unit

Slave unit

DIP Switch 1-No. 2

DIP Switch 1-No. 2

1 (Normal)

OFF

2 (Dual)

OFF

ON

7.  TURNING ON THE POWER

CAUTION

Recheck the wiring. Incorrect wiring will cause trouble.

• 

(1) Check the remote controller wiring and DIP switch settings.
(2)  Install the front case.

*  When installing the front case, connect the connector to the front case 

(in 5. INSTALLING THE REMOTE CONTROLLER).

(3)  Check the indoor and outdoor unit wiring and circuit board switch 

settings, and then turn on the indoor and outdoor units. After “

” has 

fl

 ashed on the set temperature display for several seconds, the clock 

display will appear in the center of the remote controller display.

SU MO TU WE TH FR SA

8.  SETTING THE ROOM TEMPERATURE 

DETECTION LOCATION

The detection location of the room temperature can be selected from the 

• 

following 2 examples. Choose the detection location that is best for the 
installation location. 

A. Indoor unit setting (factory setting)

The room temperature is detected by the indoor unit temperature sensor.
(1)  When the “

” button is pressed, the lock 

display 

fl

 ashes because the function is locked at the factory.

A

Indoor unit

B. Indoor unit/remote controller setting (room temperature sensor       
 selection)

The temperature sensor of the indoor unit or the remote controller can be 
used to detect the room temperature.
When use this function, set “Indoor room temperature sensor switching 
function (Function Number:42)” of “9. FUNCTION SETTING” to “Yes(01)”.
(1)  Enable the room temperature sensor selection in FUNCTION SETTING, 

which will be described later.

(2)  Press the “

” button for 5 seconds or 

more to select the temperature sensor of the indoor unit or the remote 
controller.

B

Indoor unit

CAUTION

   When select the “Remote controller setting”, if the 

detected temperature value between the temperature 
sensor of the indoor unit and the temperature sensor of 
the remote controller varies signi

fi

 cantly, it is likely to 

return to the control status of temperature sensor of the 
indoor unit temporarily.

As the temperature sensor of remote controller detects the temperature 
near the wall, when there is a certain difference between the room 
temperature and the wall temperature, the sensor will not detect the room 
temperature correctly sometimes. Especially when the outer side of the 
wall on which the sensor is positioned is exposed to the open air, it is 
recommended to use the temperature sensor of the indoor unit to detect 
the room temperature when the indoor and outdoor temperature difference 
is signi

fi

 cant.

The temperature sensor of the remote controller is not only used when 
there is a problem in the detection of the temperature sensor of the indoor 
unit.

 NOTES

If the function to change the temperature sensor is used as shown in 
example A (other than example B), be sure to lock the detection location. 
If the function is locked, the lock display 

 will 

fl

 ash when the 

” button is pressed.

9. FUNCTION SETTING

This procedure changes the function settings used to control the indoor unit 
according to the installation conditions. Incorrect settings can cause the in-
door unit to malfunction. This procedure should be performed by authorized 
installation or service personnel only.
Perform the “FUNCTION SETTING” according to the installation conditions 
using the remote controller. (Refer to the indoor unit installation manual for 
details on the function numbers and setting values.)

(1)  Press the “ 

 ” button, “ 

 ” button and 

” button simultaneously for more than 5 seconds to enter the 

function setting mode.

SU MO TU WE TH FR SA

                                                                                                                                               
(2) Press the “ 

 ” button to select the indoor unit number.

SET BACK

SU MO TU WE TH FR SA

Unit number of 
INDOOR UNIT

                                                                                                                                               

(3)  Press the “ 

 ” button or “ 

 ” buttons to select the function 

number.

Function 
number

SU MO TU WE TH FR SA

                                                                                                                                                
(4)  Press the “ 

 ” button, “ 

 ” button to select 

the setting value. The display 

fl

 ashes as shown to the right during setting 

value selection.

                                                                                                                                               

9373328162-04_IM.indb   Sec1:5

9373328162-04_IM.indb   Sec1:5

2011-12-5   14:29:31

2011-12-5   14:29:31

Содержание UTY-RNN*M series

Страница 1: ...our le personnel agréé uniquement MANUALE D INSTALLAZIONE Ad uso esclusivo del personale autorizzato РУКОВОДСТВО ПО УСТАНОВКЕ Для уполномоченного персонала INSTALLATIONSANLEITUNG Nur für autorisiertes Personal MANUAL DE INSTALACIÓN Solo para personal autorizado MANUAL DE INSTALAÇÃO Apenas para técnicos autorizados ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ Για εξουσιοδοτημένο προσωπικό σέρβις MONTAJ KILAVUZU Yetkili...

Страница 2: ...m being air conditioned will be sensed Do not locate directly exposed to the outlet air from the air conditioner Locate out of direct sunlight Locate away from the influence of other heat sources Do not touch the remote controller PC board and PC board parts directly with your hands Do not wire the remote controller cable and the bus wire together with or parallel to the connection cables transmis...

Страница 3: ...ensor Button 14 Maintenance Filter Reset Button 15 Operation Lamp 16 Day Display 17 Operation Lock Display 18 Temperature Display 19 Fan Speed Display 20 Timer Mode Display 21 Operation Mode Display 22 Timer and Clock Display 23 Filter Display 24 Economy Display 25 Thermo Sensor Display 26 Vertical Swing Display 27 Horizontal Swing Display 28 Defrost Display 4 SELECTING AN INSTALLATION LOCATION 4 ...

Страница 4: ... memory will be deleted if there is a power failure Factory setting 5 INSTALLING THE REMOTE CONTROLLER 5 1 Installation 5 1 1 INSTALLING THE REMOTE CONTROLLER Open the operation panel on the front of the remote controller remove the 2 screws indicated in the following figure and then remove the front case of the remote controller When installing the remote controller remove the connector from the ...

Страница 5: ...roller cable 20 mm 5 3 2 WHEN CONNECTING TO THE EXCLUSIVE TERMINAL BLOCK Connect the end of remote controller cable directly to the exclusive terminal block Terminal block M4 screw 3 2 1 Earth Ground the remote controller if it has an earth a ground wire Black White Red Indoor unit side PCB Indoor unit Outdoor unit power supply terminal block Remote controller terminal block Remote controller cabl...

Страница 6: ...re value between the temperature sensor of the indoor unit and the temperature sensor of the remote controller varies significantly it is likely to return to the control status of temperature sensor of the indoor unit temporarily As the temperature sensor of remote controller detects the temperature near the wall when there is a certain difference between the room temperature and the wall temperat...

Страница 7: ...s in the room If you do not wish the filter sign to be displayed select the setting value for No indication Factory setting Setting Description Function Number Setting Value Standard 11 00 Long interval 01 Short interval 02 No indication 03 The filter sign interval time is different according to Indoor unit type as follows Setting Description Compact Cassette Slim Duct Compact Wall Mounted Wall Mo...

Страница 8: ...3 11 External input control Operation Stop mode or Forced stop mode can be elected Factory setting Setting Description Function Number Setting Value Operation Stop mode 46 00 Setting forbidden 01 Forced stop mode 02 12 Room temperature control switching Only for Wired remote controller This setting is used to set the room temperature control method when the wired remote controller is selected by t...

Страница 9: ... Ex Middle temp sensor error 5 1 Indoor unit fan motor error 5 3 Drain pump error 5 7 Damper error 5 15 Indoor unit error 6 2 Outdoor unit main PCB model information error or communication error 6 3 Inverter error 6 4 Active filter error PFC circuit error 6 5 Trip terminal L error 6 10 Display PCB microcomputers communication error 7 1 Discharge temp sensor error 7 2 Compressor temp sensor error 7...

Страница 10: ......