5.1 Troubleshooting
5.1.3 Cannot Access the Serial Console
z
Is the serial connection setting correct?
Make sure to set emulator application (Tera Term, etc.) connection as follows.
5
T
roubleshoot
ing
Conditions for Communication
Value
Baud Rate
115200bps
Data Length
8bit
Parity none
Stop Bit
1bit
z
Are you using the correct conversion adapters and cables?
Check the conversion adapters (D-sub
−
RJ45, etc.) and cables being used
support serial console COM port. Optional conversion adapters are available.
Refer to
1.5.4 Serial Console Connection (page 12)
5.1.4 Cannot Operate the Device Locally
z
Are the video monitor, keyboard and mouse correctly connected?
Make sure that they are connected to the local port.
Refer to
1.5.2 Connection to the Host Server (page 10)
5.1.5 Cannot Access the Web page
z
Is the UTP cable shorter than specified limits?
The 10BASE-T and 100BASE-TX cable length must be shorter than 100m.
Make sure they are no longer than that.
z
Is the cable correctly connected?
Make sure that the Cat5 cable is connected to the Ethernet port.
Refer to
1.5.2 Connection to the Host Server (page 10)
If the network link is established, the LED in front of the device is on.
z
Is the network device power on?
SERVIS IP-KVM
1p Converter
User's Guide
145
Содержание SERVIS IP-KVM
Страница 1: ...SERVIS IP KVM 1p Converter User s Guide for ES Version 3 0 SERVIS IP KVM 1p Converter User s Guide i ...
Страница 11: ...MEMO SERVIS IP KVM 1p Converter User s Guide xi ...
Страница 12: ......
Страница 66: ...2 7 Local Operation SERVIS IP KVM 1p Converter User s Guide 54 MEMO 2 Basic Operation ...
Страница 154: ...4 4 Optional Accessories SERVIS IP KVM 1p Converter User s Guide 142 MEMO 4 Specifications ...