Sensors - Check status of the sensors
Power Supply Redundancy Configuration
I
This functionality is not available with all servers.
The
Power Supply Redundancy Configuration
group allows you to set the
redundancy mode for the managed server. It depends on the servers
capabilities which options are actually available.
PSU Redundancy 1 + 1 Spare PSU
System operation is guaranteed for 1 PSU fail in the case of 2 PSUs in
total.
PSU Redundancy 2+ 1 Spare PSU
System operation is guaranteed for 1 PSU fail in the case of 3 PSUs in
total.
PSU Redundancy 3+ 1 Spare PSU
System operation is guaranteed for 1 PSU fail in the case of 4 PSUs in
total.
AC Redundancy 2 + 2 (2 AC sources)
2 of the 4 PSUs are each connected to a separate AC source. This
ensures that the system can continue operation even if a power line or a
single PSU fails.
AC Redundancy 1 + 1 (2 AC sources)
Each PSU (of 2 PSUs in total) is connected to a separate AC source. This
ensures that the system can continue operation even if a power line or a
single PSU fails.
Содержание Remote Management
Страница 36: ...36 iRMC S2 S3 Notational conventions ...
Страница 40: ......
Страница 110: ......
Страница 134: ...134 iRMC S2 S3 Providing remote storage via a Remote Storage server ...
Страница 173: ...iRMC S2 S3 173 iRMC S2 S3 Information firmware and certificates Figure 88 Certificate Upload page ...
Страница 303: ...iRMC S2 S3 303 Console Redirection Redirecting the console Figure 183 Advanced Video Redirection page ...
Страница 320: ...320 iRMC S2 S3 Operating iRMC S2 S3 via Telnet SSH Remote Manager ...
Страница 346: ...346 iRMC S2 S3 Command Line Protocol CLP Table 18 Hierarchy of the CLP commands ...