410
iRMC
S2/S3
IPMI OEM Commands supported by the iRMC S2/S3
F5 DF - Reset Nonvolatile Cfg Variables to Default
This command forces all non-volatile IPMI settings to be set to default values.
F5 E0 - Reset ConfigSpace variables to default
This command forces all Configuration Space variables to be set to default
values.
Request Data
-
B8
NetFnlLUN: OEM/Group
-
F5
Cmd : Command Group BMC
1:3
80 28 00
IANA-Enterprise-Number FTS, LS byte first
4
DF
Command Specifier
5:8
43 4C 52 AA = ’CLR’0xaa: Security Code
Response Data
-
BC
-
F5
1
Completion Code
2:4
80 28 00
IANA-Enterprise-Number FTS, LS byte first
Request Data
-
B8
NetFnlLUN: OEM/Group
-
F5
Cmd : Command Group BMC
1:3
80 28 00
IANA-Enterprise-Number FTS, LS byte first
4
E0
Command Specifier
5:8
43 4C 52 AA = ’CLR’0xaa: Security Code
Response Data
-
BC
-
F5
1
Completion Code
2:4
80 28 00
IANA-Enterprise-Number FTS, LS byte first