Emergency flash
10.4
Emergency flash
If the iRMC S2/S3 firmware can no longer be executed, e.g. because the SDRs
are not compatible with the system, then you can use the emergency mode to
start the firmware running again. In emergency mode, the system automatically
branches to the bootloader and is the ready for the firmware update.
I
Emergency mode is indicated by the error LED (global error LED) (rot)
and the identification LED (blue) flashing alternately.
To switch the managed server to emergency mode and then update the
iRMC S2/S3's firmware, proceed as follows:
Ê
Disconnect the power supply connector.
Ê
Insert the connector in the socket again with the Identify key held down.
The managed server is now in emergency mode.
Ê
Boot the server to DOS and use the recovery flash procedure to update the
iRMC S2/S3’s firmware.
I
If the firmware is not active then the boot operation may take up to 2
minutes to start. You can ignore the error message “iRMC S2/S3
Controller Error” which the BIOS outputs during this period.
Содержание Remote Management
Страница 36: ...36 iRMC S2 S3 Notational conventions ...
Страница 40: ......
Страница 110: ......
Страница 134: ...134 iRMC S2 S3 Providing remote storage via a Remote Storage server ...
Страница 173: ...iRMC S2 S3 173 iRMC S2 S3 Information firmware and certificates Figure 88 Certificate Upload page ...
Страница 303: ...iRMC S2 S3 303 Console Redirection Redirecting the console Figure 183 Advanced Video Redirection page ...
Страница 320: ...320 iRMC S2 S3 Operating iRMC S2 S3 via Telnet SSH Remote Manager ...
Страница 346: ...346 iRMC S2 S3 Command Line Protocol CLP Table 18 Hierarchy of the CLP commands ...