![Fujitsu R410A Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/fujitsu/r410a/r410a_service-instruction_2343968015.webp)
15. MANUAL AUTO OPERATION (INDOOR UNIT BODY OPERATION)
If MANUAL AUTO Button is set, the operation is controlled as shown in Table 14.
If the remote control is lost or battery power dissipated, this function will work without the remote control.
OPERATION MODE
Auto changeover
FAN CONT. MODE
Auto
TIMER MODE
Continuous
SETTING TEMP.
76°F (24°C)
SETTING LOUVER
Standard
SWING
ECONOMY
OFF
OFF
( Table 14 : Manual auto switch operation )
(No timer setting available)
16. FORCED COOLING OPERATION
When FORCED COOLING OPERATION is set, the operation is controlled as shown is Table 15.
Forced cooling operation is started when pressing MANUAL AUTO button for 10 seconds or more.
During the forced cooling operation, it operates regardless of room temperature sensor.
Manual auto operation
OPERATION MODE
FAN CONT. MODE
TIMER MODE
SETTING TEMP.
SETTING LOUVER
SWING
ECONOMY
( Table 15 : Forced cooling operation )
Forced cooling operation
Cooling
Hi
Horizontal
OFF
Room Temp is not controlled
-
-
01-12
Operation LED and timer LED blink during the forced cooling operation. They blink for 1 second ON
and 1 second OFF on both operation LED and timer LED (same as test operation).
Forced cooling operation is released after 60 minutes of starting operation.
The FORCED COOLING OPERATION will start as shown in Table 15.
When the power was interrupted by a power failure, etc. during operation, the operation contents
at that time are memorized and when power is recovered, operation is automatically started with
the memorized operation contents.
When the power is interrupted and recovered during timer operation, since the timer operation time
is shifted by the time the power was interrupted, an alarm is given by blinking (7 sec ON/2 sec OFF)
the indoor unit body timer lamp.
[Operation contents memorized when the power is interrupted]
Operation mode
Set temperature
Set air flow
Timer mode and timer time
Set air flow Direction
Swing operation
ECONOMY operation
MINIMUM HEAT operation
14. AUTO RESTART
Содержание R410A
Страница 3: ...1 DESCRIPTION OF EACH CONTROL OPERATION R410A WALL MOUNTED type INVERTER ...
Страница 23: ...2 TROUBLE SHOOTING R410A WALL MOUNTED type INVERTER ...
Страница 63: ...3 APPENDING DATA R410A WALL MOUNTED type INVERTER ...
Страница 76: ...Jan 2016 Printed in Japan 3 3 17 Suenaga Takatsu ku Kawasaki 213 8502 Japan ...