Hot-plug/hot-swap Components
Hot-swap Hard Disk Drives
8.2.3
Installing/Removing HDD Module
V
CAUTION!
Under no circumstances should you remove a HDD module while the
system is in operation if you are not sure that the hard disk drive is
operated by a RAID controller and belongs to a disk array that is
operating in RAID level 1,5 or 10.
V
CAUTION!
The HDD module must be acclimatized in its operating environment for
an acclimatization time.
V
CAUTION!
The HDD modules must be marked clearly (see position 5 in figure 31 on
page 84) so that they can be put back into their original place after an
upgrade. If this is not taken into account, existing data can be destroyed.
I
So that the storage capacity of the hard disk can be recognized at a
glance when the hard disk drive is replaced, several prefabricated
stickers with the storage capacities are provided with the server. Each
HDD module should bear a sticker indicating its capacity on the front
(position 5 in figure 31 on page 84). Should no suitable sticker be
available, blank stickers for labeling are also provided. The stickers are
available in several colors to facilitate identification.
Temperature difference (°C)
(operating environment/outside temperature)
Minimum
acclimatization time
(hours)
5
3
10
5
15
7
20
8
25
9
30
10
Table 5: Acclimatization time for the HDD module