A26361-K881-Z102-4-7619
75
Troubleshooting and Tips
Drives Are Reported as „Dead“
7.10
Drives Are Reported as „Dead“
This error message may occur when the server has a RAID controller:
RAID controller configuration incorrect
Ê
Check and correct the settings for the drives with the RAID controller utility.
Further information is provided in the manual on the RAID controller.
7.11
Added Drive Reported Defective
This error message may occur when the server has a RAID controller:
RAID controller is not configured for this hard disk drive
The drive was probably installed when the system was switched off.
Ê
Reconfigure the RAID controller for the drive with the corresponding utility.
Information is contained in the documentation on the RAID controller.
or
Ê
Reinstall the drive while the system is switched ON.
If the hard disk drive continues to be shown as defective, then replace it (see
section “Installing/Removing HDD Module” on page 83).