312
Upgrade and Maintenance Manual
TX300 S7 / RX350 S7
Hard disk drives / solid state drives
Ê
Pull out the ID card and open the front cover as described in section
"Opening the server" on page 75
.
Ê
Remove the air duct as described in section
"Removing the system air duct"
on page 92
.
Ê
Remove the system fan holder as described in section
"Removing the
system fan holder" on page 378
.
7.4.3.3
Removing the 2x 3.5-inch HDD extension box
Figure 194: Opening the accessible drive locking bar
Ê
Remove all cables from the 2x 3.5-inch HDD extension box backplane.
Ê
If applicable, remove all cables from the slimline ODD.
Ê
If applicable, remove the LSD cable from system board connector SMB 1.
Ê
Press out on the locking latch to disengage the accessible drive locking bar
(1).
Ê
Fold up the accessible drive locking bar (2).
Содержание PRIMERGY TX300 S7
Страница 6: ...Upgrade and Maintenance Manual TX300 S7 RX350 S7 ...
Страница 32: ...32 Upgrade and Maintenance Manual TX300 S7 RX350 S7 ...
Страница 36: ...36 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Introduction ...
Страница 162: ...162 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Basic software procedures ...
Страница 188: ...188 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Power supply ...
Страница 396: ...396 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Fans ...
Страница 548: ...548 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Main memory ...
Страница 752: ...752 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Front panel and external connectors ...
Страница 822: ...822 Upgrade and Maintenance Manual TX300 S7 RX350 S7 System board and components ...
Страница 848: ...848 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Converting a tower server to a rack server ...
Страница 876: ...876 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Cabling ...