TX300 S7 / RX350 S7
Upgrade and Maintenance Manual
139
Basic software procedures
5.1.6
Switching on the ID indicator
When working in a datacenter environment, switch on the ID indicator on the
front and rear connector panels of the server for easy identification.
I
For further information, refer to section
"Locating the defective server" on
page 60
or to the "ServerView Suite Local Service Concept (LSC)"
manual available from the ServerView Suite DVD 2 supplied with your
PRIMERGY server or online at
http://manuals.ts.fujitsu.com
(EMEA
market) or
http://jp.fujitsu.com/platform/server/primergy/manual/
(Japanese
market).
Using the ID button on the front panel
Ê
Press the ID button on the front panel to switch on the system identification
LEDs.
I
For further information, refer to section
"Front panel controls and
indicators" on page 894
.
Using ServerView Operations Manager
Ê
In ServerView Operations Manager
Single System View
and press the
Locate
button in the title bar to switch on the ID indicators.
5.2
Completing the maintenance task
5.2.1
Updating or recovering the system board BIOS and
iRMC
After replacing the system board, it is essential to upgrade the BIOS and iRMC
to the latest version. The latest BIOS and iRMC versions are available from the
Fujitsu support internet pages at:
http://ts.fujitsu.com/support/
(EMEA market)
http://jp.fujitsu.com/platform/server/primergy/downloads/
(Japanese market)
I
Fujitsu does not assume responsibility for any damage done to the
server or for the loss of any data resulting from BIOS updates.
Содержание PRIMERGY TX300 S7
Страница 6: ...Upgrade and Maintenance Manual TX300 S7 RX350 S7 ...
Страница 32: ...32 Upgrade and Maintenance Manual TX300 S7 RX350 S7 ...
Страница 36: ...36 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Introduction ...
Страница 162: ...162 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Basic software procedures ...
Страница 188: ...188 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Power supply ...
Страница 396: ...396 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Fans ...
Страница 548: ...548 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Main memory ...
Страница 752: ...752 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Front panel and external connectors ...
Страница 822: ...822 Upgrade and Maintenance Manual TX300 S7 RX350 S7 System board and components ...
Страница 848: ...848 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Converting a tower server to a rack server ...
Страница 876: ...876 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Cabling ...