212
Upgrade and Maintenance Manual
TX100
S3
Processor
11.1
Basic information
I
Depending on your server model different processors are supported, see
"Model lines for TX100 S3" on page 18
.
11.2
Upgrading or replacing the processor
V
CAUTION!
Processors are extremely sensitive to electrostatic discharge and must
be handled with care. After a processor has been removed from its
protective sleeve or from its socket, place it upside down on a
nonconducting, antistatic surface. Never push a processor over a
surface.
11.2.1 Required tools
●
Preliminary and concluding steps: tool-less
●
Removing and installing the processor heat sink:
– Phillips PH2 / (+) No. 2 screw driver
●
Removing and installing the processor: tool-less
11.2.2 Preliminary steps
Before upgrading or replacing the processor, perform the following steps:
Ê
Disable BitLocker functionality as described in section
"Disabling BitLocker
functionality" on page 69
.
Field Replaceable Units (FRU)
Average hardware task duration: 15 minutes
Average software task duration: 5 minutes
Содержание PRIMERGY TX100 S3
Страница 16: ...TX100 S3 Upgrade and Maintenance Manual Version history ...
Страница 40: ...40 Upgrade and Maintenance Manual TX100 S3 Important information ...
Страница 68: ...68 Upgrade and Maintenance Manual TX100 S3 Basic hardware procedures ...
Страница 86: ...86 Upgrade and Maintenance Manual TX100 S3 Basic software procedures ...
Страница 104: ...104 Upgrade and Maintenance Manual TX100 S3 Power supply ...
Страница 126: ...126 Upgrade and Maintenance Manual TX100 S3 Hard disk drives ...
Страница 146: ...146 Upgrade and Maintenance Manual TX100 S3 System fan modules ...
Страница 200: ...200 Upgrade and Maintenance Manual TX100 S3 Expansion cards and backup units ...
Страница 234: ...234 Upgrade and Maintenance Manual TX100 S3 Processor ...
Страница 272: ...272 Upgrade and Maintenance Manual TX100 S3 Accessible drives ...
Страница 288: ...288 Upgrade and Maintenance Manual TX100 S3 Front panel and external connectors ...