172
Upgrade and Maintenance Manual
TX100
S3
Expansion cards and backup units
9.3.1.5
Concluding steps
Perform the following procedures to complete the task:
Ê
Check carefully the cable routing and close the cable clamps.
Ê
Close the side cover as described in section
"Installing the side cover" on
page 58
.
Ê
Reconnect the AC power cord to the power supply unit and secure it with a
cable tie as described in section
"Connecting the server to the mains" on
page 59
.
Ê
If applicable, update the firmware of the RAID controller that has been
connected to the BBU as described in section
"Updating RAID controller
firmware" on page 75
.
Note on BBU charging and calibration
The BBU may be deeply discharged due to extended storage time and wrongly
show as bad or defective in the ServerView RAID Manager.
In this case, the BBU will automatically enter a trickle charge cycle for recovery.
This initial charge cycle may take up to 8 hours before the BBU will initiate a
recalibration cycle.
Ê
Enter the ServerView RAID Manager and check the current BBU status.
I
For further information, please refer to the "ServerView Suite RAID
Management" user guide, available online at
http://manuals.ts.fujitsu.com
(EMEA market) or
http://jp.fujitsu.com/platform/server/primergy/manual/
(Japanese
market) or from the ServerView Suite DVD 2 supplied with your
PRIMERGY server.
Ê
If the BBU is shown as bad or defective, do not power off the server for at
least 8 hours to allow the charge and calibration cycles to finish.
Ê
If the BBU status does not change after 8 hours, please try to initiate the
recalibration process manually using the ServerView RAID Manager.
I
If this procedure still does not fix the BBU status, please contact your
local Fujitsu customer service partner.
Содержание PRIMERGY TX100 S3
Страница 16: ...TX100 S3 Upgrade and Maintenance Manual Version history ...
Страница 40: ...40 Upgrade and Maintenance Manual TX100 S3 Important information ...
Страница 68: ...68 Upgrade and Maintenance Manual TX100 S3 Basic hardware procedures ...
Страница 86: ...86 Upgrade and Maintenance Manual TX100 S3 Basic software procedures ...
Страница 104: ...104 Upgrade and Maintenance Manual TX100 S3 Power supply ...
Страница 126: ...126 Upgrade and Maintenance Manual TX100 S3 Hard disk drives ...
Страница 146: ...146 Upgrade and Maintenance Manual TX100 S3 System fan modules ...
Страница 200: ...200 Upgrade and Maintenance Manual TX100 S3 Expansion cards and backup units ...
Страница 234: ...234 Upgrade and Maintenance Manual TX100 S3 Processor ...
Страница 272: ...272 Upgrade and Maintenance Manual TX100 S3 Accessible drives ...
Страница 288: ...288 Upgrade and Maintenance Manual TX100 S3 Front panel and external connectors ...