216
Upgrade and Maintenance Manual
TX100
S3
Processor
Figure 129: Removing the processor heat sink type B (B)
Ê
Disconnect the heat sink fan connector from the system board connector
FAN CPU (1).
Ê
Carefully turn the heat sink back and forth to detach it from the processor (2).
I
This may be necessary due to the adhesive quality of the thermal
paste located between the heat sink and processor.
V
CAUTION!
Pay special attention not to damage any system board components
surrounding the processor socket.
Ê
Lift the heat sink out of the chassis (3).
Ê
Thoroughly clean residual thermal paste from the surface of the heat sink
and the processor using a lint-free cloth.
Содержание PRIMERGY TX100 S3
Страница 16: ...TX100 S3 Upgrade and Maintenance Manual Version history ...
Страница 40: ...40 Upgrade and Maintenance Manual TX100 S3 Important information ...
Страница 68: ...68 Upgrade and Maintenance Manual TX100 S3 Basic hardware procedures ...
Страница 86: ...86 Upgrade and Maintenance Manual TX100 S3 Basic software procedures ...
Страница 104: ...104 Upgrade and Maintenance Manual TX100 S3 Power supply ...
Страница 126: ...126 Upgrade and Maintenance Manual TX100 S3 Hard disk drives ...
Страница 146: ...146 Upgrade and Maintenance Manual TX100 S3 System fan modules ...
Страница 200: ...200 Upgrade and Maintenance Manual TX100 S3 Expansion cards and backup units ...
Страница 234: ...234 Upgrade and Maintenance Manual TX100 S3 Processor ...
Страница 272: ...272 Upgrade and Maintenance Manual TX100 S3 Accessible drives ...
Страница 288: ...288 Upgrade and Maintenance Manual TX100 S3 Front panel and external connectors ...