Attach the upper processor air baffle.
Insert the notches on the front side of the baffle into the front of the server.
Pass the cable through the sides of the baffle. At this time, make sure that the cable is not
pinched.
10
Attach the top cover.
6.3.4 Defective CPU Disconnection Function
This server has a defective CPU disconnection function. This function disconnects a CPU judged to be
defective (abnormal) during Power On Self Test (POST) to start the server.
For example, when two CPUs are installed and one of them is defective, the server starts to operate with
the other available CPU.
The failed CPU can be checked with the information displayed during POST or from the [CPU Status]
submenu (
pg.166) (defective CPUs are indicated with "failed") in BIOS Setup Utility.
Replace the defective CPU, if discovered, and restart the server.
Replacing a defective CPU
1
Replace the defective CPU with the new CPU following the procedure of "6.3.3
How to install CPUs" (
2
Start up BIOS Setup Utility.
"7.2.1 Starting and Exiting BIOS Setup Utility" (pg.151)
Notches
Insert the notches of the
air baffle in the tabs on the
front side of the server.
Seen from the back