RX300 S8
Upgrade and Maintenance Manual
87
Basic software procedures
5.2.6
Resetting the boot retry counter
The boot retry counter is decremented from its preset value every time the
POST watchdog initiates a system reboot. When the value has reached ’0’, the
system will shut down and power off.
5.2.6.1
Viewing the boot retry counter
The current boot retry counter status is available in the BIOS:
Ê
Enter the BIOS.
Ê
Select the
Server Mgmt
menu.
Ê
Under
Boot Retry Counter
the current number of remaining boot attempts is
displayed. The value is further decremented with every failed boot attempt
or system reboot resulting from critical system errors.
Ê
Exit the BIOS.
5.2.6.2
Resetting the boot retry counter
The boot retry counter should be reset to its original value concluding every
service task.
I
Please note, if the customer does not know about the original boot
retry values:
If the system boots up and no further errors occur within 6 hours after that
successful boot attempt, the boot retry counter will automatically be reset
to its default value. Please take into account, that the specified number
of boot attempts can only be determined after this period of time.
If the customer knows about the original boot retry values, proceed as follows
to reset or configure the boot retry counter:
Resetting the boot retry counter in the BIOS
Ê
Enter the BIOS.
Ê
Select the
Server Mgmt
menu.
Ê
Under
Boot Retry Counter
press the
[+]
or
[-]
keys to specify the maximum
number of boot attempts (0 to 7).
Ê
Exit the BIOS.
Содержание PRIMERGY RX300 S8
Страница 24: ...Upgrade and Maintenance Manual RX300 S8 Contents ...
Страница 38: ...38 Upgrade and Maintenance Manual RX300 S8 Before you start ...
Страница 72: ...72 Upgrade and Maintenance Manual RX300 S8 Basic hardware procedures ...
Страница 158: ...158 Upgrade and Maintenance Manual RX300 S8 Hard disk drives solid state drives ...
Страница 166: ...166 Upgrade and Maintenance Manual RX300 S8 System fan ...
Страница 242: ...242 Upgrade and Maintenance Manual RX300 S8 Expansion cards and backup units ...
Страница 260: ...260 Upgrade and Maintenance Manual RX300 S8 Main memory ...
Страница 277: ...RX300 S8 Upgrade and Maintenance Manual 277 Processors Figure 150 Opening the load plate B Ê Fully open the load plate ...
Страница 296: ...296 Upgrade and Maintenance Manual RX300 S8 Processors ...
Страница 482: ...482 Upgrade and Maintenance Manual RX300 S8 Cables ...
Страница 502: ...502 Upgrade and Maintenance Manual RX300 S8 Appendix ...