RX300 S8
Upgrade and Maintenance Manual
77
Basic software procedures
5.1.4
Verifying and configuring the backup software
solution
I
This task only applies to the Japanese market.
Depending on the backup software solution, it may be necessary to disable or
delete the backup drive from the backup software drive list before starting the
maintenance task.
This is the case for the following backup software solution:
– BackupExec
I
Procedures may differ depending on the backup software. For details,
refer to the dedicated documentation provided separately.
Further information on suitable backup software solutions and related
documentation is available to Fujitsu service partners from the Fujitsu
Extranet pages.
5.1.5
Note on server maintenance in a Multipath I/O
environment
When booting your server offline from the ServerView Suite DVD to perform an
offline BIOS / firmware update using the ServerView Update DVD or collect
diagnostic data using PrimeCollect in a Multipath I/O environment, there is a risk
of damaging the system configuration which may leave the system unable to
boot.
I
This is a known restriction of Windows PE with Multipath drivers.
Using Update Manager Express
Ê
If performing an offline BIOS / firmware update, first of all prepare the
ServerView Update DVD or USB stick:
Ê
Download the latest ServerView Update DVD image from Fujitsu:
for the EMEA market
ftp://ftp.ts.fujitsu.com/images/serverview
for the Japanese market:
http://jp.fujitsu.com/platform/server/primergy/products/note/svsdvd/dvd/
Содержание PRIMERGY RX300 S8
Страница 24: ...Upgrade and Maintenance Manual RX300 S8 Contents ...
Страница 38: ...38 Upgrade and Maintenance Manual RX300 S8 Before you start ...
Страница 72: ...72 Upgrade and Maintenance Manual RX300 S8 Basic hardware procedures ...
Страница 158: ...158 Upgrade and Maintenance Manual RX300 S8 Hard disk drives solid state drives ...
Страница 166: ...166 Upgrade and Maintenance Manual RX300 S8 System fan ...
Страница 242: ...242 Upgrade and Maintenance Manual RX300 S8 Expansion cards and backup units ...
Страница 260: ...260 Upgrade and Maintenance Manual RX300 S8 Main memory ...
Страница 277: ...RX300 S8 Upgrade and Maintenance Manual 277 Processors Figure 150 Opening the load plate B Ê Fully open the load plate ...
Страница 296: ...296 Upgrade and Maintenance Manual RX300 S8 Processors ...
Страница 482: ...482 Upgrade and Maintenance Manual RX300 S8 Cables ...
Страница 502: ...502 Upgrade and Maintenance Manual RX300 S8 Appendix ...