136
Upgrade and Maintenance Manual
RX300
S8
Hard disk drives / solid state drives
7.3.2.1
Preliminary steps
Ê
Locate the correct drive bay as described in section
"Mounting order for 2.5-
inch HDDs / SSDs" on page 131
.
7.3.2.2
Removing a 2.5-inch dummy module
Figure 44: Removing a 2.5-inch dummy module
Ê
Press both tabs together (1) and pull the dummy module out of its bay (2).
V
CAUTION!
Save the dummy module for future use.
Always replace dummy modules into unused HDD / SSD bays to
comply with applicable EMC regulations and satisfy cooling
requirements.