90
Upgrade and Maintenance Manual
RX300
S7
Basic software procedures
5.1.5
Note on server maintenance in a Multipath I/O
environment
When booting your server offline from the ServerView Suite DVD to perform an
offline BIOS / firmware update using the ServerView Update DVD or collect
diagnostic data using PrimeCollect in a Multipath I/O environment, there is a risk
of damaging the system configuration which may leave the system unable to
boot.
This is a known restriction of Windows PE with Multipath drivers.
Before using the ServerView Update DVD or PrimeCollect in an offline
environment, Fujitsu recommends to properly shut down the server and to
disconnect all external I/O connections (like LAN or FC cables) from the system.
Only keep mouse, keyboard, video cable and AC power cord connected.
Continue as follows:
Ê
If performing an offline BIOS / firmware update, first of all prepare the
ServerView Update DVD:
Ê
Download the latest ServerView Update DVD image from the Fujitsu
FTP server at:
ftp://ftp.ts.fujitsu.com/images/serverview
Ê
Burn the image to a DVD.
For the Japanese market:
Ê
Locate, download and burn the ServerView Update DVD image available
from the following URL:
http://jp.fujitsu.com/platform/server/primergy/products/note/svsdvd/dvd/
Ê
Ensure that all external I/O connections have been removed from the server.
I
Ensure that all external I/O connections are uniquely identified so that
you can reconnect them into their original locations after concluding
the task.
Ê
Switch on the server.
Ê
Right after switching on the server, insert the ServerView Suite DVD into the
DVD drive and close the drive tray.
The server will now boot from the DVD.
Ê
After the boot process is complete, select your preferred GUI language.
Содержание PRIMERGY RX300 S7
Страница 6: ...Upgrade and Maintenance Manual RX300 S7 ...
Страница 26: ...26 Upgrade and Maintenance Manual RX300 S7 ...
Страница 30: ...30 Upgrade and Maintenance Manual RX300 S7 Introduction ...
Страница 42: ...42 Upgrade and Maintenance Manual RX300 S7 Before you start ...
Страница 116: ...116 Upgrade and Maintenance Manual RX300 S7 Basic software procedures ...
Страница 136: ...136 Upgrade and Maintenance Manual RX300 S7 Power supply ...
Страница 176: ...176 Upgrade and Maintenance Manual RX300 S7 Hard disk drives solid state drives ...
Страница 186: ...186 Upgrade and Maintenance Manual RX300 S7 System fan ...
Страница 306: ...306 Upgrade and Maintenance Manual RX300 S7 Processors Figure 160 Opening the load plate B Ê Fully open the load plate ...
Страница 317: ...RX300 S7 Upgrade and Maintenance Manual 317 Processors Figure 170 Opening the load plate B Ê Fully open the load plate ...
Страница 334: ...334 Upgrade and Maintenance Manual RX300 S7 Processors ...
Страница 406: ...406 Upgrade and Maintenance Manual RX300 S7 Accessible drives ...
Страница 498: ...498 Upgrade and Maintenance Manual RX300 S7 System board and components ...
Страница 524: ...524 Upgrade and Maintenance Manual RX300 S7 Conversion configurations ...
Страница 560: ...560 Upgrade and Maintenance Manual RX300 S7 Appendix ...