RX300 S7
Upgrade and Maintenance Manual
435
Front panel
If the server has been completely removed from the rack for maintenance
purposes, reinstall and secure it in the rack as described in section
"Mounting the server in the rack" on page 77
.
Ê
"Connecting the server to the power source" on page 81
Ê
"Closing the rack door" on page 84
Ê
"Enabling BitLocker functionality" on page 107
13.3.1.8 Using the front management LAN connector
In order to use the front management LAN connector to access the iRMC S3
management controller, please proceed as follows:
Ê
Ensure that
Management LAN
has been enabled in the BIOS:
Ê
Enter the BIOS.
Ê
Select the
Server Mgmt
menu.
Ê
Under
iRMC LAN Parameters Configuration
, make sure that the
Management LAN
setting is set to
Enabled
.
Ê
Save your changes and exit the BIOS.
I
The front management LAN connector can be used to access the
iRMC S3 with either of the
Management LAN Port
settings enabled,
Management
or
Shared
.
For detailed information on how to access the BIOS and modify
settings, refer to the "D2939 BIOS Setup Utility for PRIMERGY
RX300 S7" reference manual.
Ê
Connect a client computer (e.g. notebook) to the front management LAN
connector.
I
It is not possible to simultaneously access the iRMC S3 from the front
and rear management LAN connectors. As soon as a LAN cable is
connected to the front management LAN connector, the iRMC S3
cannot be accessed via the rear management LAN connector.
After removing the LAN cable from the front management LAN
connector, the iRMC S3 will immediately become accessible via the
rear management LAN connector again.
Содержание PRIMERGY RX300 S7
Страница 6: ...Upgrade and Maintenance Manual RX300 S7 ...
Страница 26: ...26 Upgrade and Maintenance Manual RX300 S7 ...
Страница 30: ...30 Upgrade and Maintenance Manual RX300 S7 Introduction ...
Страница 42: ...42 Upgrade and Maintenance Manual RX300 S7 Before you start ...
Страница 116: ...116 Upgrade and Maintenance Manual RX300 S7 Basic software procedures ...
Страница 136: ...136 Upgrade and Maintenance Manual RX300 S7 Power supply ...
Страница 176: ...176 Upgrade and Maintenance Manual RX300 S7 Hard disk drives solid state drives ...
Страница 186: ...186 Upgrade and Maintenance Manual RX300 S7 System fan ...
Страница 306: ...306 Upgrade and Maintenance Manual RX300 S7 Processors Figure 160 Opening the load plate B Ê Fully open the load plate ...
Страница 317: ...RX300 S7 Upgrade and Maintenance Manual 317 Processors Figure 170 Opening the load plate B Ê Fully open the load plate ...
Страница 334: ...334 Upgrade and Maintenance Manual RX300 S7 Processors ...
Страница 406: ...406 Upgrade and Maintenance Manual RX300 S7 Accessible drives ...
Страница 498: ...498 Upgrade and Maintenance Manual RX300 S7 System board and components ...
Страница 524: ...524 Upgrade and Maintenance Manual RX300 S7 Conversion configurations ...
Страница 560: ...560 Upgrade and Maintenance Manual RX300 S7 Appendix ...