RX300 S7
Upgrade and Maintenance Manual
45
Important information
●
Ethernet cabling has to comply with EN 50173 and EN 50174-1/2 standards
or ISO/IEC 11801 standard respectively. The minimum requirement is a
Category 5 shielded cable for 10/100 Ethernet, or a Category 5e cable for
Gigabit Ethernet.
●
Route the cables in such a way that they do not create a potential hazard
(make sure no-one can trip over them) and that they cannot be damaged.
When connecting the server, refer to the relevant instructions in this manual.
●
Never connect or disconnect data transmission lines during a storm (risk of
lightning hazard).
●
Make sure that no objects (e.g. jewelry, paperclips etc.) or liquids can get
inside the server (risk of electric shock, short circuit).
●
In emergencies (e.g. damaged casing, controls or cables, penetration of
liquids or foreign bodies), contact the system administrator or your customer
service team. Only disconnect the system from the mains power supply if
there is no risk of harming yourself.
●
Proper operation of the system (in accordance with IEC 60950-1 resp.
EN 60950-1) is only ensured if the casing is completely assembled and the
rear covers for the installation slots have been fitted (electric shock, cooling,
fire protection, interference suppression).
●
Only install system expansions that satisfy the requirements and rules
governing safety and electromagnetic compatibility and those relating to
telecommunication terminals. If you install other expansions, they may
damage the system or violate the safety regulations. Information on which
system expansions are approved for installation can be obtained from our
customer service center or your sales outlet.
●
The components marked with a warning notice (e.g. lightning symbol) may
only be opened, removed or exchanged by authorized, qualified personnel.
Exception: CSS components can be replaced.
●
The warranty is void if the server is damaged during installation or
replacement of system expansions.
●
Only set screen resolutions and refresh rates that are specified in the
operating manual for the monitor. Otherwise, you may damage your monitor.
If you are in any doubt, contact your sales outlet or customer service center.
●
Before installing/removing internal options to/from the server, turn off the
server, all peripheral devices, and any other connected devices. Also unplug
all power cords from the outlet. Failure to do so can cause electric shock.
Содержание PRIMERGY RX300 S7
Страница 6: ...Upgrade and Maintenance Manual RX300 S7 ...
Страница 26: ...26 Upgrade and Maintenance Manual RX300 S7 ...
Страница 30: ...30 Upgrade and Maintenance Manual RX300 S7 Introduction ...
Страница 42: ...42 Upgrade and Maintenance Manual RX300 S7 Before you start ...
Страница 116: ...116 Upgrade and Maintenance Manual RX300 S7 Basic software procedures ...
Страница 136: ...136 Upgrade and Maintenance Manual RX300 S7 Power supply ...
Страница 176: ...176 Upgrade and Maintenance Manual RX300 S7 Hard disk drives solid state drives ...
Страница 186: ...186 Upgrade and Maintenance Manual RX300 S7 System fan ...
Страница 306: ...306 Upgrade and Maintenance Manual RX300 S7 Processors Figure 160 Opening the load plate B Ê Fully open the load plate ...
Страница 317: ...RX300 S7 Upgrade and Maintenance Manual 317 Processors Figure 170 Opening the load plate B Ê Fully open the load plate ...
Страница 334: ...334 Upgrade and Maintenance Manual RX300 S7 Processors ...
Страница 406: ...406 Upgrade and Maintenance Manual RX300 S7 Accessible drives ...
Страница 498: ...498 Upgrade and Maintenance Manual RX300 S7 System board and components ...
Страница 524: ...524 Upgrade and Maintenance Manual RX300 S7 Conversion configurations ...
Страница 560: ...560 Upgrade and Maintenance Manual RX300 S7 Appendix ...