RX300 S7
Upgrade and Maintenance Manual
523
Conversion configurations
15.3.7 Configuration 7 to configuration 8
Ê
Replace multicage with the panelhousing and a HDD cage as described in
section
"Replacing the front cages" on page 517
.
Ê
Connect cable C7 from connector X1 of the 4x 2.5-inch SAS backplane to
connector X3 of the 12x 2.5-inch SAS backplane
15.4 Concluding steps
Perform the following procedures to complete the task:
Ê
"Installing the fan box" on page 184
Ê
"Installing the air duct" on page 74
Ê
"Mounting the server cover" on page 76
Ê
"Sliding the server into the rack" on page 80
If the server has been completely removed from the rack for maintenance
purposes, reinstall and secure it in the rack as described in section
"Mounting the server in the rack" on page 77
.
Ê
Reconnect all external cables.
Ê
"Connecting the server to the power source" on page 81
Ê
"Closing the rack door" on page 84
Ê
Update your server’s chassis information on the Chassis ID EPROM
integrated into the front panel board. For further information on how to obtain
and use the
ChassisId_Prom
Tool, refer to section
"Using the Chassis ID
Prom Tool" on page 111
.
Ê
"Enabling BitLocker functionality" on page 107
Содержание PRIMERGY RX300 S7
Страница 6: ...Upgrade and Maintenance Manual RX300 S7 ...
Страница 26: ...26 Upgrade and Maintenance Manual RX300 S7 ...
Страница 30: ...30 Upgrade and Maintenance Manual RX300 S7 Introduction ...
Страница 42: ...42 Upgrade and Maintenance Manual RX300 S7 Before you start ...
Страница 116: ...116 Upgrade and Maintenance Manual RX300 S7 Basic software procedures ...
Страница 136: ...136 Upgrade and Maintenance Manual RX300 S7 Power supply ...
Страница 176: ...176 Upgrade and Maintenance Manual RX300 S7 Hard disk drives solid state drives ...
Страница 186: ...186 Upgrade and Maintenance Manual RX300 S7 System fan ...
Страница 306: ...306 Upgrade and Maintenance Manual RX300 S7 Processors Figure 160 Opening the load plate B Ê Fully open the load plate ...
Страница 317: ...RX300 S7 Upgrade and Maintenance Manual 317 Processors Figure 170 Opening the load plate B Ê Fully open the load plate ...
Страница 334: ...334 Upgrade and Maintenance Manual RX300 S7 Processors ...
Страница 406: ...406 Upgrade and Maintenance Manual RX300 S7 Accessible drives ...
Страница 498: ...498 Upgrade and Maintenance Manual RX300 S7 System board and components ...
Страница 524: ...524 Upgrade and Maintenance Manual RX300 S7 Conversion configurations ...
Страница 560: ...560 Upgrade and Maintenance Manual RX300 S7 Appendix ...