CAUTION
▶
Advise your contact persons that they must provide you with all
recovery keys which belong to the system to restore them in the
TPM later.
Preliminary steps
▶
"Locating the defective server" on page 43
.
▶
"Suspending BitLocker functionality" on page 69
.
▶
If applicable,
"Removing the front cover with lock" on page 45
▶
"Shutting down the server" on page 46
▶
"Disconnecting the power cord" on page 47
▶
"Removing a hot-plug PSU" on page 105
.
▶
"Getting access to the component" on page 49
▶
"Removing the air duct" on page 65
.
▶
"Removing the defective fan module" on
.
▶
"Removing a riser module" on page 63
.
▶
Remove the system board, see
"Removing the defective system board" on
.
Removing the defective TPM
▶
Remove the TPM, see
"Removing the TPM" on page 301
▶
Leave the TPM spacer on the system board when removing the defective
TPM.
Installing the new TPM
The TPM spacer is already present on the system board.
▶
Install the TPM, see
"Installing the TPM" on page 296
.
System board and components
304
Upgrade and Maintenance Manual
RX1330 M5
Содержание PRIMERGY RX1330 M5
Страница 68: ...Basic hardware procedures 68 Upgrade and Maintenance Manual RX1330 M5 ...
Страница 118: ...Power supply unit PSU 118 Upgrade and Maintenance Manual RX1330 M5 ...
Страница 178: ...Fans 178 Upgrade and Maintenance Manual RX1330 M5 ...
Страница 230: ...Main memory 230 Upgrade and Maintenance Manual RX1330 M5 ...
Страница 256: ...Accessible drives 256 Upgrade and Maintenance Manual RX1330 M5 ...
Страница 282: ...Front panel 282 Upgrade and Maintenance Manual RX1330 M5 ...
Страница 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M5 ...
Страница 336: ...System board and components 336 Upgrade and Maintenance Manual RX1330 M5 ...
Страница 362: ...Appendix A 362 Upgrade and Maintenance Manual RX1330 M5 ...
Страница 364: ...FUJITSU Server PRIMERGY RX1330 M5 Reference Manual Reference Manual English Cable Plan for September 2021 ...
Страница 388: ...25 RX1330M5 SERIAL ext Cable Plan CA05973 7065 PCIe SLOT2 System Board D3929 SERIAL System Board D3929 SERIAL ...
Страница 390: ...FUJITSU Server PRIMERGY RX1330 M5S Reference Manual Reference Manual English Cable Plan for March 2021 ...
Страница 403: ...14 RX1330M5S SERIAL ext Cable Plan CA05973 7065 PCIe SLOT2 System Board D3929 SERIAL ...
Страница 405: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT June 2021 ...