When the system is powered on after a CPU has been replaced or
upgraded, the Global Error indicator will start flashing with the message
CPU has been changed
.
This only indicates that the CPU configuration has been altered. There
is no technical problem.
Proceed as follows:
●
Restart your server.
●
As soon as the startup screen appears, press the [F2] function key to
enter the BIOS.
●
If a password is assigned, enter the password and press [Enter].
●
Select the
Save & Exit
menu.
●
Select
Save Changes and Exit
or
Save Changes and Reset
.
●
Verify that the Global Error indicator stops flashing.
▶
"Enabling replaced components in the BIOS" on page 81
▶
"Resuming BitLocker functionality" on page 86
.
11.4
Replacing the heat sink
Field Replaceable Unit
(FRU)
Hardware: 15 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver
Depending on ATD support, there are different heat sinks available.
Preliminary steps
▶
"Locating the defective server" on page 43
▶
"Removing the front cover with lock" on page 45
.
▶
"Shutting down the server" on page 46
.
Processor (CPU)
RX1330 M5
Upgrade and Maintenance Manual
241
Содержание PRIMERGY RX1330 M5
Страница 68: ...Basic hardware procedures 68 Upgrade and Maintenance Manual RX1330 M5 ...
Страница 118: ...Power supply unit PSU 118 Upgrade and Maintenance Manual RX1330 M5 ...
Страница 178: ...Fans 178 Upgrade and Maintenance Manual RX1330 M5 ...
Страница 230: ...Main memory 230 Upgrade and Maintenance Manual RX1330 M5 ...
Страница 256: ...Accessible drives 256 Upgrade and Maintenance Manual RX1330 M5 ...
Страница 282: ...Front panel 282 Upgrade and Maintenance Manual RX1330 M5 ...
Страница 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M5 ...
Страница 336: ...System board and components 336 Upgrade and Maintenance Manual RX1330 M5 ...
Страница 362: ...Appendix A 362 Upgrade and Maintenance Manual RX1330 M5 ...
Страница 364: ...FUJITSU Server PRIMERGY RX1330 M5 Reference Manual Reference Manual English Cable Plan for September 2021 ...
Страница 388: ...25 RX1330M5 SERIAL ext Cable Plan CA05973 7065 PCIe SLOT2 System Board D3929 SERIAL System Board D3929 SERIAL ...
Страница 390: ...FUJITSU Server PRIMERGY RX1330 M5S Reference Manual Reference Manual English Cable Plan for March 2021 ...
Страница 403: ...14 RX1330M5S SERIAL ext Cable Plan CA05973 7065 PCIe SLOT2 System Board D3929 SERIAL ...
Страница 405: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT June 2021 ...