Appendix
24
2 PRECAUTIONS
The following describes precautions when using the remote service board.
2.1 Voltage/Temperature Sensor No.
Voltage/temperature sensor Nos. on the remote service board are assigned from 0.
For this reason, the voltage/temperature sensor Nos. of the server unit displayed in related
software (ServerView, RemoteControlService, Web Interface) and the voltage/temperature
sensor Nos. in error messages shift by the number of remote service boards.
Voltage No.:
4
Temperature sensor No.: 1
The following are examples of displayed according to the number of remote service boards
mounted.
■
When this board is not mounted
[Voltage]
[Temperature sensor]
No.
Name
No.
Application
0
CPU0
0
housing
1
CPU1
1
CPU
:
:
:
:
■
When this board is mounted
[Voltage]
[Temperature sensor]
No.
Name
No.
Application
0
RSB ExtPower
0
housing (temperature on this board)
1
RSB PCI Power
1
housing
2
RSB AUX Power
2
CPU
3
RSB Main Power
:
:
4
CPU0
:
:
5
CPU1
:
:
:
:
:
:
2.2 Initial Setup
Setup is as follows when the remote service board is installed.
z
Software Watchdog with ServerView setup
: Disabled
z
Power ON/OFF Timer with ServerView setup
: Disabled