188
Upgrade and Maintenance Manual
CX272
S1
System board and components
9.2
USB Flash Module (UFM)
The server node can be equipped with a USB Flash Module (UFM).
9.2.1
Installing the UFM board
9.2.1.1
Preliminary steps
Perform the following procedures:
Ê
"Disabling SVOM boot watchdog functionality" on page 75
Ê
Locate the desired server with the ID button.
Ê
"Shutting down the server node" on page 41
Ê
If applicable, remove all external cables from the server node.
Ê
"Removing the server node from the Dual Node Cluster Server" on page 42
Upgrade and Repair Unit
(URU)
Hardware: 5 minutes
Software: 5 minutes
Tools:
– Phillips PH1 / (+) No. 1 screw driver
Содержание PRIMERGY CX272 S1