12
Service Supplement
PRIMERGY CX122 S1
Safety notes
V
CAUTION!
●
This device must only be connected to the rack's internal power
distribution unit, no external power cords.
●
Ensure that the PRIMERGY CX1000 S1 system unit is connected to
a properly grounded power outlet close to the device.
●
Ensure that the power sockets on the PRIMERGY CX1000 S1
system unit and the properly grounded power outlets are freely
accessible.
●
The On/Off button or the main power switch (if present) does not
isolate the device from the mains power supply. To disconnect it
completely from the mains power supply, remove the server from the
PRIMERGY CX1000 S1 system unit and replace it by a dummy cover
(see sections
section "Removing a PRIMERGY CX122 S1 server
from the system unit" on page 19
and
).
●
Data cables must be adequately shielded.
●
Ethernet cabling has to comply with EN 50173 and EN 50174-1/2
standards or ISO/IEC 11801 standard respectively. The minimum
requirement is a Category 5 shielded cable for 10/100 Ethernet, or a
Category 5e cable for Gigabit Ethernet.
●
Route the cables in such a way that they do not create a potential
hazard (make sure no-one can trip over them) and that they cannot
be damaged. When connecting the server, refer to the relevant
instructions in this manual.
●
Never connect or disconnect data transmission lines during a storm
(risk of lightning hazard).
●
Make sure that no objects (e.g. jewelry, paperclips etc.) or liquids can
get inside the server (risk of electric shock, short circuit).
●
In emergencies (e.g. damaged casing, controls or cables, penetration
of liquids or foreign bodies), switch off the server immediately,
disconnect the PRIMERGY CX1000 S1 system unit from the mains
and contact your sales outlet or customer service team.
●
Proper operation of the system (in accordance with IEC 60950-1/2
resp. EN 60950-1/2) is only ensured if the casing is completely
assembled (electric shock, cooling, fire protection, interference
suppression).