PRIMERGY CX122 S1
Service Supplement
73
Installing / replacing memory modules
4.6.1
Removing a memory module
Ê
Open the server as described in
section "Opening the server" on page 31
.
Ê
If applicable, remove the CPU 1 air duct as described in
Figure 51: Removing a memory module
Ê
Eject the defective memory module by pressing out the securing clips at
each end of the memory module connector.
V
CAUTION!
In order to satisfy cooling requirements, please note:
When removing a memory module that is not replaced immediately,
always install a memory dummy module in the empty memory slot as
described in
section "Removing / installing a memory dummy
!
Содержание PRIMERGY CX122 S1
Страница 1: ...Service Supplement English PRIMERGY CX122 S1 Server Service Supplement November 2010 ...
Страница 10: ......
Страница 12: ......
Страница 20: ......
Страница 27: ...PRIMERGY CX122 S1 Service Supplement 25 Preparations Figure 8 LAN cabling color coding servers ...
Страница 92: ......