PRIMERGY 10GbE Connection Blade 18/8 User Guide
7 / 95
1.1.4
Reset Switch (F)
The PRIMERGY 10GbE Connection Blade 18/8 has a reset switch to restart this Connection Blade (hard
reset) and to boot up backup firmware.
Hard Reset:
Push the reset Switch and then release it soon.
Boot up Backup Firmware:
Push the reset switch until port LEDs start blinking green (about 5sec to 10sec) and then release it.
Note
You can enter the backup firm by pressing Ctrl-B while "Booting ..." message is displayed.
1.1.5
Hardware Specifications
Table 3 shows the hardware specifications of the PRIMERGY 10GbE Connection Blade 18/8.
Item
Specifications
Interface
ETHER(LAN)port
Standard
IEEE 802.3
Downlink port
(
port1-18
)
18 ports
(
10GBASE-KR
)
Uplink port
(
port19-26
)
8ports
(
10GBASE-LR/SR/CR (SFP+)
)
Management blade
connection port
(oob
)
1port
(10/100Base-T,Ethernet connection
via management blade)
Console Port
Standard
RS-232C
#of ports
1
Data transfer rate
9600bps
Connection mode
Serial connection via management blade
Operating Voltage
DC +12 V
Power Consumption
Max 36W
External dimensions
(
H x D x W
)
29 x 268 x 193 (mm)
Weight
1.5 kg
Ambient Requirements
[Temperature]
On operation:5 ~35 degrees C
Table3. Hardware Specifications