PRIMERGY 10GbE Connection Blade 18/8 User Guide
25 / 95
3.2.2
Configuring Link Aggregation with LACP
This section describes how to configure link aggregation with LACP with 4 links.
<Configuration target>
Configure link aggregation with LACP with Interface0/19-0/22
Assign VLAN(VID20) to IP address(192.168.20.1/24)
<Commands>
SBAX2#1
Assign Interface0/19-0/22 to tag VLAN(VID10,20)
(config)#interface range 0/19-0/22
(config-if)#vlan tag 10,20
Configure link aggregation with LACP with Interface0/19-0/22 and set active mode
(config)#interface range 0/19-0/22
(config-if)#type linkaggregation 1
(config)#linkaggregation 1 mode active
Assign IP address(192.168.20.1/24) to VLAN(VID20)
(config)#lan 0 ip address 192.168.20.1/24 3
(config)#lan 0 vlan20
Save the configuration
(config)#save
SBAX2#2
Assign Interface0/19-0/22 to tag VLAN(VID10,20)
(config)#interface range 0/19-0/22
(config-if)#vlan tag 10,20
Configure link aggregation with LACP with Interface0/19-0/22 and set active mode
(config)#interface range 0/19-0/22
(config-if)#type linkaggregation 1
(config)#linkaggregation 1 mode active
Assign IP address(192.168.20.2/24) to VLAN(VID20)
(config)#lan 0 ip address 192.168.20.2/24 3
(config)#lan 0 vlan20
Save the configuration
(config)#save
SBAX2#1
SBAX2#2