MMB CLI (Command Line Interface) Operations
2.6 PRIMEQUEST 2800B2/2800B model Commands
540
CA92344-0539-04
2.6.44 show raid disk_enclosure
Displays disk enclosures information attached to the specified RAID adapter.
Privilege: A
ll
(1) Input format
show raid disk_enclosure [IOU | PCI_BOX] <UNIT#>-<PCISLOT#> {encl=<Port#>-
<Cascade#>}
(2) Option
encl: This option specifies port number and cascade number for the target disk enclosure. (ex. encl=0-0).
(3) Usage example
Example: When you display disk enclosures attached to the RAID adapter on IOU#2-PCI slot#3.
# show raid disk_enclosure IOU 2-3
Port
Cascade
Vendor
Product
Type
0
0
FUJITSU
JX40
0302
0
1
FUJITSU
JX40
0302
1
0
FUJITSU
JX40
0302
1
1
FUJITSU
JX40
0302
Example: When you display the disk enclosure attached to port#0-cascade#0 of RAID adapter on
IOP#2-PCI slot#3.
# show raid disk_enclosure IOU 2-3 encl=0-0
Product Name:
FUJITSU ETERNUS JX40
Status:
OK
Vendor:
FUJITSU
Product:
JX40
Port number:
0
Cascade:
1
DeviceID:
48
SAS address:
51463080001ABC3E
Firmware version:
0302
(4) Message
The following table lists the messages which are displayed in this CLI.
For details of the messages, see the PRIMEQUEST 2000 Series Message Reference (CA92344-0540)..
No enclosure is connected to the controller.
Too much arguments argc=%d.
Too few arguments argc=%d.
The specified parameter is invalid. %s
The specified controller is not found.
The specified enclosure is not connected.
Internal error [%d:%d].
The operation is failed. %s
Unable to execute the command because the %s is under maintenance.