MMB Web-UI (Web User Interface) Operations
1.3 [Partition] Menu for PRIMEQUEST 2400E2/2800E2/2400E/2800E
169
CA92344-0539-04
Remarks
Radio button is attached for the display of each Free SB, IOU and Extended Partitioning, and it is not
possible to select more than one at the same time.
In case of PRIMEQUEST 2800E2/2880E model, check whether SB in which one CPU can be mounted, is
not mounted in the partitions of two or more SBs.
Only when one partition is configured by one SB, one CPU can be mounted for one SB.
When one partition is configured by multiple SBs, it is mandatory to mount two CPUs for each SB in the
partition.
When Memory Scale-up Board is built into the partition, it is necessary to build one or more SB into the
partition.
If the maintenance mode (Hot Partition Maintenance, Warm System Maintenance or Cold system
Maintenance) is set, only the user (Maintenance person, Administrator privilege) who sets the maintenance
mode can operate this mode.
In case of the partition other than the maintenance target, a message is displayed and operation is not
possible.
The addition of Memory Scale-up Board to Partition that Dynamic Reconfiguration Mode is effective cannot
be set by warning Dialog box being displayed.
TABLE 1.70 Display Items and Set Items of [Add SB/IOU to Partition] Window
Items
Description
Free SB/IOU/Extended Partitioning
Displays the SB/IOU/ Extended Partitioning in the free
status (Status which does not belong to any partition)
Status
Displays the status of the SB/IOU/Extended Partitioning.
Note
SB
Number of
CPUs
Displays the number of CPU mounted on the SB.
This item is not displayed for Memory Scale-up Board.
Memory
Displays the amount of memory mounted on the SB.
IOU
Number of
PCI-Express
slots
Displays the number of PCI-Express slots of the IOU.
Extended
Partitioning
There is no display.