C141-E045-02EN
5 - 38
At command issuance (I/O registers setting contents)
1F7
H
(CM)
1
0
0
1
0
0
0
0
1F6
H
(DH)
×
×
×
DV
xx
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(FR)
xx
xx
xx
xx
xx
At command completion (I/O registers contents to be read)
1F7
H
(ST)
Status information
1F6
H
(DH)
×
×
×
DV
xx
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(ER)
xx
xx
01
H
(*1)
01
H
Diagnostic code
*1 This register indicates X‘00’ in the LBA mode.
(17)
FORMAT TRACK (X'50')
Upon receipt of this command, the device sets the DRQ bit and waits the completion of 512-
byte format parameter transfer from the host system. After completion of transfer, the device
clears the DRQ bits, sets the BSY bit. However the device does not perform format operation,
but the drive clears the BYS bit and generates an interrupt soon. When the command
execution completes, the device clears the BSY bit and generates an interrupt.
The drive supports this command for keep the compatibility with previous drive only.
(18)
READ LONG (X'22' or X'23')
This command operates similarly to the READ SECTOR(S) command except that the device
transfers the data in the requested sector and the ECC bytes to the host system. The ECC error
correction is not performed for this command. This command is used for checking ECC
function by combining with the WRITE LONG command.
Number of ECC bytes to be transferred is fixed to 4 bytes and cannot be changed by the SET
FEATURES command.
The READ LONG command supports only single sector operation.
Содержание MPB3021AT
Страница 1: ...C141 E045 02EN MPB3021AT MPB3032AT MPB3043AT MPB3052AT MPB3064AT DISK DRIVES PRODUCT MANUAL ...
Страница 3: ......
Страница 7: ......
Страница 15: ......
Страница 31: ......
Страница 33: ...C141 E045 02EN 3 2 Figure 3 1 Dimensions ...
Страница 48: ...C141 E045 02EN 4 5 Figure 4 2 MPB30xxAT Block diagram ...
Страница 54: ...C141 E045 02EN 4 11 Figure 4 4 Read write circuit block diagram ...
Страница 56: ...C141 E045 02EN 4 13 Figure 4 6 PR4 signal transfer ...