C141-E045-02EN
5 - 22
At command completion (I/O registers contents to be read)
1F7
H
(ST)
Status information
1F6
H
(DH)
×
L
×
DV
End head No. /LBA [MSB]
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(ER)
End cylinder No. [MSB] / LBA
End cylinder No. [LSB] / LBA
End sector No.
/ LBA [LSB]
00 (*1)
Error information
*1 If the command is terminated due to an error, the remaining number of
sectors of which data was not transferred is set in this register.
(5)
WRITE SECTOR(S) (X'30' or X'31')
This command writes data of sectors from the address specified in the Device/Head, Cylinder
High, Cylinder Low, and Sector Number registers to the address specified in the Sector Count
register. Number of sectors can be specified to 256 sectors in maximum. Data transfer begins
at the sector specified in the Sector Number register. For the DRQ, INTRQ, and BSY
protocols related to data transfer, see Subsection 4.4.2.
If the head is not on the track specified by the host, the device performs a implied seek. After
the head reaches to the specified track, the device writes the target sector.
The data stored in the buffer, and CRC code and ECC bytes are written to the data field of the
corresponding sector(s). Upon the completion of the command execution, the command block
registers contain the cylinder, head, and sector addresses of the last sector written.
If an error occurs during multiple sector write operation, the write operation is terminated at
the sector where the error occurred. Command block registers contain the cylinder, the head,
the sector addresses (in the CHS mode) or the logical block address (in the LBA mode) of the
sector where the error occurred. Then the host can read the command block registers to
determine what error has occurred and on which sector the error has occurred.
At command issuance (I/O registers setting contents)
1F7
H
(CM)
0
0
1
1
0
0
0
R
1F6
H
(DH)
×
L
×
DV
Start head No. /LBA [MSB]
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(FR)
Start cylinder No. [MSB]/ LBA
Start cylinder No. [LSB] / LBA
Start sector No.
/ LBA [LSB]
Transfer sector count
xx
R = 0
→
with Retry
R = 1
→
without Retry
Содержание MPB3021AT
Страница 1: ...C141 E045 02EN MPB3021AT MPB3032AT MPB3043AT MPB3052AT MPB3064AT DISK DRIVES PRODUCT MANUAL ...
Страница 3: ......
Страница 7: ......
Страница 15: ......
Страница 31: ......
Страница 33: ...C141 E045 02EN 3 2 Figure 3 1 Dimensions ...
Страница 48: ...C141 E045 02EN 4 5 Figure 4 2 MPB30xxAT Block diagram ...
Страница 54: ...C141 E045 02EN 4 11 Figure 4 4 Read write circuit block diagram ...
Страница 56: ...C141 E045 02EN 4 13 Figure 4 6 PR4 signal transfer ...