C141-E045-02EN
6 - 2
6.1.1
Response to power-on
After the master device (device 0) releases its own power-on reset state, the master device
shall check a DASP- signal for up to 450 ms to confirm presence of a slave device (device 1).
The master device recognizes presence of the slave device when it confirms assertion of the
DASP- signal. Then, the master device checks a PDIAG- signal to see if the slave device has
successfully completed the power-on diagnostics.
If the master device cannot confirm assertion of the DASP- signal within 450 ms, the master
device recognizes that no slave device is connected.
After the slave device (device 1) releases its own power-on reset state, the slave device shall
report its presence and the result of power-on diagnostics to the master device as described
below:
DASP- signal: Asserted within 400 ms.
PDIAG- signal: Negated within 1 ms and asserted within 30 seconds.
Max. 400 ms.
Max. 30 sec.
Max. 1 ms.
If presence of a slave device is
confirmed, PDIAG- is checked for
up to 31 seconds.
Checks DASP- for up to
450 ms.
Max. 31 sec.
DASP-
PDIAG-
BSY bit
Power On Reset-
Status Reg.
BSY bit
Power On Reset-
Slave device
Master device
Power on
Figure 6.1
Response to power-on
Содержание MPB3021AT
Страница 1: ...C141 E045 02EN MPB3021AT MPB3032AT MPB3043AT MPB3052AT MPB3064AT DISK DRIVES PRODUCT MANUAL ...
Страница 3: ......
Страница 7: ......
Страница 15: ......
Страница 31: ......
Страница 33: ...C141 E045 02EN 3 2 Figure 3 1 Dimensions ...
Страница 48: ...C141 E045 02EN 4 5 Figure 4 2 MPB30xxAT Block diagram ...
Страница 54: ...C141 E045 02EN 4 11 Figure 4 4 Read write circuit block diagram ...
Страница 56: ...C141 E045 02EN 4 13 Figure 4 6 PR4 signal transfer ...