Error Analysis
7.2.2
Sense data (3-0C-03), (4-32-01), (4-40-xx), (4-C4-xx), and (4-44-xx)
Sense data (3-0C-03), (4-32-01), (4-40-xx), (4-C4-xx), and (4-44-xx) indicate one of the following:
•
A target sector could not be detected using the sector counter.
•
A seek process overran the specified time.
•
A write to a disk terminated abnormally.
•
An error occurred in power-on self-diagnosis.
•
An HDD error occurred.
The symptoms above are generally caused by an error in a PCBA or DE.
7.2.3
Sense data (1-1x-xx), (3-1x-xx) and (E-1D-00): Disk read error
If sense data (1-1x-xx), (3-1x-xx) or (E-1D-00) occurs frequently in a specific block of a disk, there
is disk damage that was not recorded in the media defect list. In this case, assign an alternate block
to the error-detected block using a REASSIGN BLOCKS command. For an explanation of the
REASSIGN BLOCKS command, refer to Subsection 4.3.2 "REASSIGN BLOCKS (07)" of the
FIBRE CHANNEL INTERFACE MANUAL.
If this error occurs in different blocks, a PCBA or DE is faulty.
7.2.4
Sense data (5-2x-xx), (B-47-xx), (B-4B-xx) and (B-4E-00): interface error
Sense data (5-2x-xx), (B-47-xx), (B-4B-xx) and (B-4E-00) indicates one of the following symptoms:
•
An invalid or unsupported command was issued, or invalid or unsupported parameters were
specified.
•
An interface error occurred.
If this error occurs, the PCBA or the interface is faulty.
88
C141-E264
Содержание MBA3073FD
Страница 1: ...C141 E264 01EN MBA3300FD MBA3147FD MBA3073FD HARD DISK DRIVES PRODUCT MANUAL ...
Страница 4: ...This page is intentionally left blank ...
Страница 12: ...This page is intentionally left blank ...
Страница 32: ...This page is intentionally left blank ...
Страница 74: ...This page is intentionally left blank ...
Страница 90: ...This page is intentionally left blank ...
Страница 96: ...This page is intentionally left blank ...
Страница 102: ...This page is intentionally left blank ...
Страница 104: ...This page is intentionally left blank ...
Страница 105: ......
Страница 106: ......