5.4 Checking Operation after Installation and Preparing the HDDs for Use
5.4.4 Setting
parameters
The user can specify the optimal operation mode for the user system environments by setting the
following parameters with the MODE SELECT or MODE SELECT EXTENDED command:
•
Error recovery parameter
•
Caching parameter
•
Control mode parameter
•
Fibre channel control parameter
With the MODE SELECT or MODE SELECT EXTENDED command, specify 1 for the "SP" bit on
CDB to save the specified parameter value on the disk. This enables the HDD to operate by using
the parameter value set by the user when power is turned on again.
When the parameters are not set or saved with the MODE SELECT or MODE SELECT
EXTENDED command, the HDD sets the default values for parameters and operates when power is
turned on or after reset. Although the HDD operations are assured with the default values, the
operations are not always optimal for the system. To obtain the best performance, set the parameters
in consideration of the system requirements specific to the user.
This section outlines the parameter setting procedures. Refer to Subsection 4.1.4 "MODE
SELECT (15)", 4.1.5 "MODE SELECT EXTENDED (55)" of the FIBRE CHANNEL INTERFACE
MANUAL for further details of the MODE SELECT and MODE SELECT EXTENDED commands
and specifying the parameters.
1.
At factory shipment of the HDDs, the saving operation for the MODE
SELECT parameter is not executed. So, if the user does not set
parameters, the HDDs operates according to the default value of each
parameter
2.
The MODE SELECT parameter is not saved for each initiator ID but as
the common parameter for all initiators. In the mult-initiator system,
parameter setting cannot be changed for each initiator.
3.
Once parameters are saved, the saved value is effective as long as next
saving operation is executed from the initiator. For example, even if the
initialization of the disk is performed by the FORMAT UNIT command,
the saved value of parameters described in this section is not affected.
4.
When the HDDs, to which the saving operation has been executed on a
system, is connected to another system, the user must pay attention to
that the HDDs operates according to the saved parameter value if the
saving operation is not executed at installation.
5.
The saved value of the MODE SELECT parameter is assumed as the
initial value of each parameter after the power-on, the RESET condition.
The initiator can change the parameter value temporary (actively) at any
timing by issuing the MODE SELECT or MODE SELECT EXTENDED
command with specifying "0" to the SP bit in the CDB.
C141-E264
63
Содержание MBA3073FD
Страница 1: ...C141 E264 01EN MBA3300FD MBA3147FD MBA3073FD HARD DISK DRIVES PRODUCT MANUAL ...
Страница 4: ...This page is intentionally left blank ...
Страница 12: ...This page is intentionally left blank ...
Страница 32: ...This page is intentionally left blank ...
Страница 74: ...This page is intentionally left blank ...
Страница 90: ...This page is intentionally left blank ...
Страница 96: ...This page is intentionally left blank ...
Страница 102: ...This page is intentionally left blank ...
Страница 104: ...This page is intentionally left blank ...
Страница 105: ......
Страница 106: ......