Command Specifications
4-68
C141-C012
Table 4.31 MRIE (1/2)
MRIE Descriptor
X’00’
No reporting of informational exception conditions:
This method instructs the target to not report informational exception
conditions.
X’01’
(setting
prohibited)
Asynchronous event reporting:
This method instructs the target to report informational exception conditions
by using the rules for asynchronous event reporting as described in the
SCSI-3 Architecture Model and the relevant Protocol Standard.
The sense key shall be set to RECOVERED ERROR and the additional
sense code shall indicate the cause of the informational exception condition.
X’02’
Generate unit attention:
This method instructs the target to report informational exception conditions
by returning a CHECK CONDITION status on any command. The sense
key shall be set to UNIT ATTENTION and the additional sense code shall
indicate the cause of the informational exception condition.
The command that has the CHECK CONDITION shall not be executed
before the informational exception condition is reported.
X’03’
Conditionally generate recovered error:
This method instructs the target to report informational exception
conditions, dependent on the value of the per bit of the error recovery
parameters mode page, by returning a CHECK CONDITION status on any
command. The sense key shall be set to RECOVERED ERROR and the
additional sense code shall indicate the cause of the informational exception
condition.
The command that has the CHECK CONDITION shall complete without
error before any informational exception condition may be reported.
X’04’
Unconditionally generate recovered error:
This method instructs the target to report informational exception
conditions, regardless of the value of the per bit of the error recovery
parameters mode page, by returning a CHECK CONDITION status on any
command.. The sense key shall be set to RECOVERED ERROR and the
additional sense code shall indicate the cause of the informational exception
condition.
The command that has the CHECK CONDITION shall complete without
error before any informational exception condition may be reported.
Содержание MAX3036RC SERIES
Страница 4: ...This page is intentionally left blank ...
Страница 128: ...This page is intentionally left blank ...
Страница 136: ...This page is intentionally left blank ...
Страница 338: ...This page is intentionally left blank ...
Страница 368: ...This page is intentionally left blank ...
Страница 378: ...This page is intentionally left blank ...
Страница 380: ...This page is intentionally left blank ...
Страница 394: ...This page is intentionally left blank ...
Страница 396: ...This page is intentionally left blank ...
Страница 398: ......
Страница 399: ......
Страница 400: ......