Command Specifications
4-168
C141-C012
4.3.3 READ DEFECT DATA (37)
Bit
Byte
7 6 5 4 3 2 1 0
0 X‘37’
1 0 0 0 0 0 0 0 0
2 0 0 0
PList
GList Defect
List
Format
3 0 0 0 0 0 0 0 0
4 0 0 0 0 0 0 0 0
5 0 0 0 0 0 0 0 0
6 0 0 0 0 0 0 0 0
7
Transfer Byte Length (MSB)
8
Transfer Byte Length (LSB)
9 0 0 0 0 0 0 0 0
This command transfers the list described in the defect position information of the
disk media (defect data) to the INIT.
There are two types of defect data, the P List (primary defect list) and the G list
(grown defect list). The P List indicates the defect position information at the time the
disk drive was shipped from the factory. On the other hand, the G List shows the
defect position information specified from the INIT by the REASSIGN BLOCKS
command or automatic alternate block allocation processing, or when executing the
FORMAT UNIT command, or defective data block positional information from
alternate block allocation from Verify operation after initialization.
The INIT can specify the defect data type transferred to the INIT by the “P List
(primary list)” bit and “G List (grown list)” bit in the CDB and can specify the
defect data format by the “Defect List Format” field.
Table 4.109 Defect data type
PList
GList
Defect Data Type
1
1
P List and G List
1
0
P List only
0
1
G List only
0
0
4-byte header information only (described in this section)
Содержание MAX3036RC SERIES
Страница 4: ...This page is intentionally left blank ...
Страница 128: ...This page is intentionally left blank ...
Страница 136: ...This page is intentionally left blank ...
Страница 338: ...This page is intentionally left blank ...
Страница 368: ...This page is intentionally left blank ...
Страница 378: ...This page is intentionally left blank ...
Страница 380: ...This page is intentionally left blank ...
Страница 394: ...This page is intentionally left blank ...
Страница 396: ...This page is intentionally left blank ...
Страница 398: ......
Страница 399: ......
Страница 400: ......