4.1 Control/Sense Commands
C141-C012
4-33
Table 4.16 Combination of error recovery flags (1/4)
EER
PER
DTE
DCR
Error Recovery Procedure
0
0
0
0
1. Rereading is tried repeatedly up to the number of times specified in the "Read
Retry Count", "Write Retry Count" or "Verify Retry Count" parameter. If
possible, data correction is executed afterward according to the ECC.
2. When error recovery has succeeded, processing of the command is continued.
3. The contents of recovered errors are not reported.
4. If unrecoverable errors have been detected, execution of that command is
terminated at that point.
5. Transfer of data in blocks which include unrecoverable errors to the INIT is
done in accordance with the specification in the TB bit (read commands).
0
0
0
1
1. Rereading is tried repeatedly up to the number of times specified in the "Read
Retry Count", "Write Retry Count" or "Verify Retry Count" parameter. Data
correction is not executed according to the ECC.
2. When error recovery has succeeded, processing of the command is continued.
3. The contents of recovered errors are not reported.
4. If unrecoverable errors have been detected, execution of that command is
terminated at that point.
5. Transfer of data in blocks which include unrecoverable errors to the INIT is
done in accordance with the specification in the TB bit (read commands).
0
0
1
0
(Setting prohibited) (See *1 at the end of this table.)
0
0
1
1
(Setting prohibited) (See *1 at the end of this table.)
0
1
0
0
1. Rereading is tried repeatedly up to the number of times specified in the "Read
Retry Count", "Write Retry Count" or "Verify Retry Count" parameter. If
possible, data correction is executed afterward according to the ECC.
2. When error recovery has succeeded, processing of the command is continued.
3. If unrecoverable errors have been detected, execution of that command is
terminated at that point.
4. Transfer of data in blocks which include unrecoverable errors to the INIT is
done in accordance with the specification in the TB bit (read commands).
5. When recovery from all detected errors has been successful, a CHECK
CONDITION status (RECOVERED ERROR [=1]) is reported after all
processing of the command is completed and the sense data indicate the
content of the last error that was successfully recovered from and the address
of the data block where that error occurred.
Содержание MAX3036RC SERIES
Страница 4: ...This page is intentionally left blank ...
Страница 128: ...This page is intentionally left blank ...
Страница 136: ...This page is intentionally left blank ...
Страница 338: ...This page is intentionally left blank ...
Страница 368: ...This page is intentionally left blank ...
Страница 378: ...This page is intentionally left blank ...
Страница 380: ...This page is intentionally left blank ...
Страница 394: ...This page is intentionally left blank ...
Страница 396: ...This page is intentionally left blank ...
Страница 398: ......
Страница 399: ......
Страница 400: ......