![Fujitsu MAX3036RC SERIES Скачать руководство пользователя страница 346](http://html.mh-extra.com/html/fujitsu/max3036rc-series/max3036rc-series_specifications_121519346.webp)
Sense Data and Error Recovery Methods
5-8
C141-C012
Table 5.4 Additional Sense Code and Additional Sense Code Qualifier (2/6)
C*
Q* Name
Explanation
Sense
key
01 Information Unit Too Short
The received write data is shorter than the stipulated length.
B
0E
02 Information Unit Too Long
The received write data is longer than the stipulated length.
B
01 Read retries exhausted
Unrecovered error was detected during data read (retry out).
3, B
11
02 Error too long to correct
Unrecovered error was detected during data read (BCRC error
detected by SAS/IF)
3, B
13 00
Sync Mark not found for Data
field
SM (Sync Mark) could not be detected in the Data area.
1, 3, B
00 Record entity not found
Expected data from a sector was undetected. (LBA compare
error detected by FMT)
1, 3, B
14
01 Record not found
The target data block (sector) could not be detected.
1, 3, B
01 Mechanical positioning Error A seek error occurred in the drive.
1, 3, B
15
02 Positioning Error detected by
read of medium
LBA did not match due to Cylinder number’s mismatch.
1, 3, B
01 Recovered data with retries
A data error was recovered from by reading was retried.
1
02 Recovered data with positive
head offset
A data error was recovered by read retry with offsetting head to
positive direction.
1
03 Recovered data with negative
head offset
A data error was recovered by read retry with offsetting head to
negative direction.
1
06 Recovered data without ECC:
data auto-reallocated
Automatic alternate allocation was applied without ECC
correcting a data error.
1
17
08 Recovered data without ECC:
recommended rewrite
Rewriting to the same sector was performed without ECC
correcting a data error.
1
18
00 Recovered Data with Error
Correction Applied
A data error was recovered by read retry with ECC correcting.
1
02 Defect list error in primary list An error was detected during reading of the defect list (P List).
3
03 Defect list error in grown list
An error was detected during reading of the defect list (G List).
3
80 Log information read error
An error was detected during reading of statistical information.
3
81 Log information write error
A write error was detected during writing of statistical
information.
3
84 Mode Select SA write Error
An error was detected during writing of SA information (Mode
Select Parameter)
3
Ax Drive Parameter SA write
Error
An error was detected during writing of SA information (Device
Information)
3
19
Bx Drive Parameter SA write
Error
An error was detected during writing of SA information (Device
Information)
3
1A
00 Parameter list length error
There is a mistake in the indication of the parameter list page
length.
5
* C: Additional Sense Code, Q: Additional Sense Code Qualifier
Содержание MAX3036RC SERIES
Страница 4: ...This page is intentionally left blank ...
Страница 128: ...This page is intentionally left blank ...
Страница 136: ...This page is intentionally left blank ...
Страница 338: ...This page is intentionally left blank ...
Страница 368: ...This page is intentionally left blank ...
Страница 378: ...This page is intentionally left blank ...
Страница 380: ...This page is intentionally left blank ...
Страница 394: ...This page is intentionally left blank ...
Страница 396: ...This page is intentionally left blank ...
Страница 398: ......
Страница 399: ......
Страница 400: ......