When the value specified in the "Page code" field is other than X '3F', the specified "Page
descriptor" only is transferred to the INIT, and when X '3F' is specified, all the "Page
descriptors" supported by the IDD are transferred to the INIT in the ascending order of the
page code. Also, when X '00' is specified in the "Page code field," the "Page descriptor" is not
transferred. If page codes other than the abovementioned ones ("Page descriptors" which are
not supported by the IDD) are specified, the command is terminated with a CHECK
CONDITION status (ILLEGAL REQUEST [=5] / Invalid field in CDB [=24-00]).
Also the "PC (page control)" field in CDB byte 2 specifies the type of parameter value in the
"Page descriptor" transferred to the INIT by this command, as shown in Table 4.2.
IMPORTANT
Even in cases where the value specified in the MODE SELECT or
MODE SELECT EXTENDED command is described in Table 4.2
as the value reported to the INIT by this command, if parameter
rounding processing is applied by the IDD, or in cases of a
parameter or bit with a specified value that is disregarded,
different values than those specified by the INIT will be reported.
For details, see the descriptions of each page descriptor (in
Section 4.1.5). Also, "0" is reported in byte positions and bit
positions which are reserved in each page descriptor.
Содержание MAA3182FC Series
Страница 5: ...This page is intentionally left blank ...
Страница 9: ...viii C141 E054 02EN This page is intentionally left blank ...
Страница 11: ...This page is intentionally left blank ...
Страница 21: ...This page is intentionally left blank ...
Страница 131: ...This page is intentionally left blank ...
Страница 143: ...This page is intentionally left blank ...
Страница 311: ...This page is intentionally left blank ...
Страница 313: ...This page is intentionally left blank ...
Страница 324: ...This page is intentionally left blank ...
Страница 327: ......