OPERATING TIPS

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

Low Ambient Cooling

z

  When the outdoor temperature drops, the outdoor unit’s 

fans may switch to Low Speed, or one of the fans may 
stop intermittently.

* Hot start

The indoor unit prevents cold drafts when heating opera-
tion begins.
The indoor unit fan will not operate until the heat exchanger 
reaches the set temperature. 

About ECONOMY OPERATION

At the maximum output, ECONOMY OPERATION is approxi-
mately 75% of normal air conditioner operation for cooling 
and heating.

z

  If the room is not cooled (or heated) well during economy 

operation, select normal operation.

z

  During the monitor period in the AUTO mode, the air 

conditioner operation will not change to ECONOMY 
OPERATION even if ECONOMY OPERATION is selected 
by pressing the ECONOMY button.

Dual Remote Controllers (optional)

An additional remove controller can be added up to the 
maximum of two remote controllers. Either remote controller 
can control the air conditioner. However, the timer functions 
cannot be used at the slave unit.

Group Control

One remote controller can control up to 16 air conditioners.
All of the air conditioners will be operated with the same 
settings.

*Heating Performance

z

  This air conditioner operates on the heat-pump principle, 

absorbing heat from outdoor air and transferring that 
heat indoors. As a result, the operating performance is 
reduced as outdoor air temperature drops. If you feel that 
insuffi cient heating performance is being produced, we 
recommend you use this air conditioner in conjunction 
with another kind of heating appliance.

z

  Heat-pump air conditioners heat your entire room by 

recirculating air throughout the room, with the result 
that some time may be required after fi rst starting the air 
conditioner until the room is heated.

*When Indoor and Outdoor Tempera-
ture are High

z

  When both indoor and outdoor temperatures are high 

during use of the heating mode, the outdoor unit’s fan 
may stop at times.

Fan speed: AUTO

*Heating:  The fan will operate at very low speed when the 

temperature of the air issued from the indoor unit 
is low.

Cooling:  As the room temperature approaches that of the 

set temperature, the fan speed becomes slower.    

Fan: 

  The fan runs at the low fan speed.

*Microcomputer-controlled Automatic 
Defrosting

z

  When using the Heating mode under conditions of low 

outdoor temperature and high humidity, frost may form 
on the outdoor unit, resulting in reduced operating per-
formance.

  In order to prevent this kind of reduced performance, 

this unit is equipped with a Microcomputer-controlled 
Automatic Defrosting function. During the defrost cycle, 
the indoor fan will shutdown and 

 will be displayed 

on the remote controller. It will take anywhere from 4 to 
20 minutes before the air conditioner starts up again.

9374379385.indd   Sec1:12

9374379385.indd   Sec1:12

11/3/09   8:48:34 AM

11/3/09   8:48:34 AM

Содержание Inverter ART Series

Страница 1: ...ntains and operates with refrigerant R410A THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED BY QUALIFIED PERSONNEL Refer to Commonwealth State Territory and local legislation regulations codes installation operation manuals before the installation maintenance and or service of this product 9374379385 indd 1 9374379385 indd 1 11 3 09 8 48 25 AM 11 3 09 8 48 25 AM ...

Страница 2: ...ace animals or plants in the direct path of the air flow z When restarting after a long period of disuse in the winter turn the power switch on at least 6 hours before starting the unit z Do not drink the water drained from the air conditioner z Do not use in applications involving the storage of foods plants or animals precision equipment or art works z Do not apply any heavy pressure to radiator ...

Страница 3: ...al Airflow Direction and Swing Button 1 Horizontal Airflow Direction and Swing Button 2 FILTER RESET Button 3 Operation Lamp Timer and Clock Display Operation Mode Display Fan Speed Display Operation Lock Display Temperature Display Function Display Defrost Display Thermo Sensor Display Economy Display 1 3 These functions cannot be used o i u p a t 1 e 5 r q 0 3 4 w 8 6 2 y 9 7 9374379385 indd Sec1 ...

Страница 4: ...ons to set the current time Press repeatedly to adjust the current time in 1 minute increments Press and hold to adjust the current time in 10 minute increments ex Monday PM11 00 Press again to end SU MO TU WE TH FR SA 1 3 5 Press the SET BACK button to switch between the 12 and 24 hour time displays 3 4 SU MO TU WE TH FR SA SU MO TU WE TH FR SA SET BACK Set the current day and time 9374379385 ind...

Страница 5: ... AUTO Press the SET TEMP buttons to set the room temperature Press the FAN button to set the fan speed Press the ECONOMY button to start or stop ECONOMY OPERA TION For details on the function refer to page 12 Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle To start stop operation To set the operation mode z Operation mode setting z Room temperature setting z F...

Страница 6: ...mperature is detected at the indoor unit remote sensor or the remote controller When the thermo sensor display appears the room temperature is detected at the remote controller NOTES This function is locked at the factory In order to detect the room temperature correctly consult authorized service personnel when using this function If this function is locked the location where the room temperature...

Страница 7: ... be used to repeat the timer settings for all of the days Temperature SET BACK timer See page 9 Use this timer function to change the set temperature in the operation times set for each day of the week This can be used together with other timer settings ON OFF TIMER Press the TIMER MODE button to select the ON timer or OFF timer 2 Press the TIMER DELETE button to cancel the timer mode The timer mo...

Страница 8: ... day Press the DAY button to complete the time setting and return to the day of the week setting When the operating time is set the mark appears 5 Repeat steps 3 and 4 To complete the weekly timer settings press the TIMER SET button for 2 seconds or more z To delete the operating time If the TIMER DELETE button is pressed during steps 3 or 4 the operating time for the selected day will be deleted ...

Страница 9: ...cel Follow the same procedures as those for setup ex The DAY OFF is set for Monday NOTES The DAY OFF setting is only available for days for which weekly settings already exist If the operating time carries over to the next day during a next day setting the effective DAY OFF range will be set as shown below z Normal z Next day setting Setting day Preceding day Next day Setting day Preceding day Nex...

Страница 10: ... 15 18 21 ex When setting all days together z Temperature setting Press the SET TEMP buttons to set the temperature The temperature setting range is the same as the range for the operation mode ex Operating time 15 00 22 00 5 Repeat steps 3 and 4 Press the TIMER SET button for 2 seconds or more to complete the temperature SET BACK timer settings ON OFF 24 C 24 C 28 C SET BACK temperature Normal te...

Страница 11: ...AUTION WARNING In the event of a malfunction burning smell etc immediately stop operation turn off the electrical breaker and consult authorized service personnel Merely turning off the unit s power switch will not completely disconnect the unit from the power source Always be sure to turn off the electrical breaker to ensure that power is completely off Before requesting service perform the follo...

Страница 12: ... to time Also the fan may operate at very low speed when adjusting room humidity z In the monitor AUTO operation the fan will operate at very low speed Water is produced from the outdoor unit z During Heating operation water may be produced from the out door unit due to the Automatic Defrosting operation 12 thermo sensor display on the remote controller is flashing z The room temperature sensor may...

Страница 13: ...sferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insufficient heating performance is being produced we recommend you use this air conditioner in conjunction with another kind of heating appliance z Heat pump air conditioners heat your entire room by recirculating air throughout the room with the result that some time may b...

Страница 14: ...mance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time During Automatic Defrosting operation the heat operation will be interrupted z After the start of heating operation it takes sometime before the room gets warmer Cooling z Use to cool your room Dry z Use for gently cooling while dehumidifying your room z You cannot heat the room...

Страница 15: ...he automatic protection circuit may operate interrupting the operation If the unit is used under lower temperature conditions than those noted here the heat exchanger may freeze causing water leakage or other malfunction z Do not use the air conditioner for any purpose other than room cooling dry room heating or fan SELF DIAGNOSIS SU MO TU WE TH FR SA When EE in Temperature Display is displayed in...

Страница 16: ...FUJITSU GENERAL LIMITED 1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan 9374379385 indd Sec1 15 9374379385 indd Sec1 15 11 3 09 8 48 35 AM 11 3 09 8 48 35 AM ...

Отзывы: