background image

9

TEMPERATURE SET BACK TIMER

Press the SET BACK button to change to the SET BACK con-
fi rmation display.
The SET BACK operating time and the set temperature will 
be displayed.

2

Press the TIMER SET button 
for 2 seconds or more.

1

3

z

 Day setting 

z

 Operating time setting

Follow the same procedures to set the operating time as those for the weekly timer. The TIMER DELETE button is 
also used as described in the procedures for the weekly timer.

4

 NOTES

•  The SET BACK timer only changes the set temperature, it cannot be used to start or stop air conditioner operation.
•  The SET BACK timer can be set to operate up to two times per day but only one temperature setting can be used.
•  The SET BACK timer can be used together with the ON, OFF, and weekly timer functions.
•  The SET BACK operating time is displayed only in the SET BACK confi rmation display. (Refer to step 1 for the SET BACK 

confi rmation display.)

SET BACK

SU MO TU WE TH FR SA

3 6 9 12 15 18 21

SU MO TU WE TH FR SA

3 6 9 12 15 18 21

ex. When setting all days together

z

 Temperature setting

Press the SET TEMP. buttons to set the 
temperature. (The temperature setting 
range is the same as the range for the 
operation mode.)

ex. Operating time 15:00–22:00

5

Repeat steps 

3

 and 

4

.

Press the TIMER SET button for 
2 seconds or more to complete 
the temperature SET BACK timer 
settings.

ON

OFF

24

°

C

24

°

C

28

°

C

SET BACK temperature

Normal temperature

z

 To start

SET BACK

Press the SET BACK button. The SET BACK confi rmation display appears 
for 5 seconds, and then the timer starts automatically.

ex. Display during SET BACK timer operation

(The operating time will not be displayed.)

z

 To cancel

Press the SET BACK button, and then 
press the TIMER DELETE button while 
the SET BACK confi rmation display is 
displayed. Even if the SET BACK but-
ton is pressed again, the SET BACK 
timer will be cancelled.

SU MO TU WE TH FR SA

3 6 9 12 15 18 21

If there is no existing 
SET BACK tempera-
ture setting, “- -” will 
be displayed for the 
temperature.

SU MO TU WE TH FR SA

1

3

2

4

1

2

Temperature SET BACK timer setting

Temperature SET BACK timer operation

9374379385.indd   Sec1:9

9374379385.indd   Sec1:9

11/3/09   8:48:32 AM

11/3/09   8:48:32 AM

Содержание Inverter ART Series

Страница 1: ...ntains and operates with refrigerant R410A THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED BY QUALIFIED PERSONNEL Refer to Commonwealth State Territory and local legislation regulations codes installation operation manuals before the installation maintenance and or service of this product 9374379385 indd 1 9374379385 indd 1 11 3 09 8 48 25 AM 11 3 09 8 48 25 AM ...

Страница 2: ...ace animals or plants in the direct path of the air flow z When restarting after a long period of disuse in the winter turn the power switch on at least 6 hours before starting the unit z Do not drink the water drained from the air conditioner z Do not use in applications involving the storage of foods plants or animals precision equipment or art works z Do not apply any heavy pressure to radiator ...

Страница 3: ...al Airflow Direction and Swing Button 1 Horizontal Airflow Direction and Swing Button 2 FILTER RESET Button 3 Operation Lamp Timer and Clock Display Operation Mode Display Fan Speed Display Operation Lock Display Temperature Display Function Display Defrost Display Thermo Sensor Display Economy Display 1 3 These functions cannot be used o i u p a t 1 e 5 r q 0 3 4 w 8 6 2 y 9 7 9374379385 indd Sec1 ...

Страница 4: ...ons to set the current time Press repeatedly to adjust the current time in 1 minute increments Press and hold to adjust the current time in 10 minute increments ex Monday PM11 00 Press again to end SU MO TU WE TH FR SA 1 3 5 Press the SET BACK button to switch between the 12 and 24 hour time displays 3 4 SU MO TU WE TH FR SA SU MO TU WE TH FR SA SET BACK Set the current day and time 9374379385 ind...

Страница 5: ... AUTO Press the SET TEMP buttons to set the room temperature Press the FAN button to set the fan speed Press the ECONOMY button to start or stop ECONOMY OPERA TION For details on the function refer to page 12 Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle To start stop operation To set the operation mode z Operation mode setting z Room temperature setting z F...

Страница 6: ...mperature is detected at the indoor unit remote sensor or the remote controller When the thermo sensor display appears the room temperature is detected at the remote controller NOTES This function is locked at the factory In order to detect the room temperature correctly consult authorized service personnel when using this function If this function is locked the location where the room temperature...

Страница 7: ... be used to repeat the timer settings for all of the days Temperature SET BACK timer See page 9 Use this timer function to change the set temperature in the operation times set for each day of the week This can be used together with other timer settings ON OFF TIMER Press the TIMER MODE button to select the ON timer or OFF timer 2 Press the TIMER DELETE button to cancel the timer mode The timer mo...

Страница 8: ... day Press the DAY button to complete the time setting and return to the day of the week setting When the operating time is set the mark appears 5 Repeat steps 3 and 4 To complete the weekly timer settings press the TIMER SET button for 2 seconds or more z To delete the operating time If the TIMER DELETE button is pressed during steps 3 or 4 the operating time for the selected day will be deleted ...

Страница 9: ...cel Follow the same procedures as those for setup ex The DAY OFF is set for Monday NOTES The DAY OFF setting is only available for days for which weekly settings already exist If the operating time carries over to the next day during a next day setting the effective DAY OFF range will be set as shown below z Normal z Next day setting Setting day Preceding day Next day Setting day Preceding day Nex...

Страница 10: ... 15 18 21 ex When setting all days together z Temperature setting Press the SET TEMP buttons to set the temperature The temperature setting range is the same as the range for the operation mode ex Operating time 15 00 22 00 5 Repeat steps 3 and 4 Press the TIMER SET button for 2 seconds or more to complete the temperature SET BACK timer settings ON OFF 24 C 24 C 28 C SET BACK temperature Normal te...

Страница 11: ...AUTION WARNING In the event of a malfunction burning smell etc immediately stop operation turn off the electrical breaker and consult authorized service personnel Merely turning off the unit s power switch will not completely disconnect the unit from the power source Always be sure to turn off the electrical breaker to ensure that power is completely off Before requesting service perform the follo...

Страница 12: ... to time Also the fan may operate at very low speed when adjusting room humidity z In the monitor AUTO operation the fan will operate at very low speed Water is produced from the outdoor unit z During Heating operation water may be produced from the out door unit due to the Automatic Defrosting operation 12 thermo sensor display on the remote controller is flashing z The room temperature sensor may...

Страница 13: ...sferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insufficient heating performance is being produced we recommend you use this air conditioner in conjunction with another kind of heating appliance z Heat pump air conditioners heat your entire room by recirculating air throughout the room with the result that some time may b...

Страница 14: ...mance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time During Automatic Defrosting operation the heat operation will be interrupted z After the start of heating operation it takes sometime before the room gets warmer Cooling z Use to cool your room Dry z Use for gently cooling while dehumidifying your room z You cannot heat the room...

Страница 15: ...he automatic protection circuit may operate interrupting the operation If the unit is used under lower temperature conditions than those noted here the heat exchanger may freeze causing water leakage or other malfunction z Do not use the air conditioner for any purpose other than room cooling dry room heating or fan SELF DIAGNOSIS SU MO TU WE TH FR SA When EE in Temperature Display is displayed in...

Страница 16: ...FUJITSU GENERAL LIMITED 1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan 9374379385 indd Sec1 15 9374379385 indd Sec1 15 11 3 09 8 48 35 AM 11 3 09 8 48 35 AM ...

Отзывы: