NOTES:
• The air conditioner custom code is set to prior to shipment.
• If you do not know the air conditioner custom code setting, try each of the custom codes ( →
→ → ) until you find the code that operates the air conditioner.
¢
Contents of function setting
Each function setting listed in this section is adjustable in accordance with the installation environ-
ment.
NOTE:
Setting will not be changed if invalid numbers or setting values are selected.
Function setting list
Function no.
Functions
1)
00
Remote controller address setting
2)
11
Filter sign
3)
30/31
Room temperature control for indoor unit sensor
4)
35/36
Room temperature control for wired remote controller sensor
5)
40
Auto restart
6)
42
Room temperature sensor switching
7)
44
Remote controller custom code
8)
46
External input control
9)
48
Room temperature sensor switching (Aux.)
10)
49
Indoor unit fan control for energy saving for cooling
1) Remote controller address setting
Multiple indoor units can be operated by using one wired remote controller.
Set the unit number of each indoor unit.
Function number
Setting value
Setting description
Factory setting
00
00
Unit no. 0
♦
01
Unit no. 1
02
Unit no. 2
03
Unit no. 3
04
Unit no. 4
05
Unit no. 5
06
Unit no. 6
07
Unit no. 7
08
Unit no. 8
09
Unit no. 9
10
Unit no. 10
11
Unit no. 11
12
Unit no. 12
13
Unit no. 13
14
Unit no. 14
15
Unit no. 15
NOTE:
When different type of indoor units (such as wall mounted type and cassette type, cassette
type and duct type, or other combinations) are connected using group control system, some
functions may no longer be available.
- 29 -
11-1. Function settings by using remote controller
11. Function settings
WALL MOUNTED
ASHG18, 24KMTA
WALL MOUNTED
ASHG18, 24KMTA