1. Specifications
Type
Wall mounted
Inverter heat pump
Model name
ASHG18KMTA
ASHG24KMTA
Power supply
230 V ~ 50 Hz
Power supply intake
Outdoor unit
Available voltage range
198—264 V
Capacity
Cooling
Rated
kW
5.20
7.10
Btu/h
17,700
24,200
Min.—Max.
kW
0.90—6.00
0.90—8.30
Btu/h
3,100—20,500
3,100—28,300
Heating
Rated
kW
6.30
8.00
Btu/h
21,500
27,200
Min.—Max.
kW
0.90—8.70
0.90—10.10
Btu/h
3,100—29,600
3,100—34,400
Input power
Cooling
Rated
kW
1.39
2.08
Min.—Max.
0.09—1.66
0.24—3.15
Heating
Rated
1.56
1.91
Min.—Max.
0.09—2.86
0.14—3.00
Fan
HIGH
W
37.5
61.6
MED
22.9
26.7
LOW
13.3
13.3
QUIET
8.2
8.2
Current
Cooling
Rated
A
6.1
9.3
Heating
7.0
8.6
EER
Cooling
kW/kW
3.74
3.41
COP
Heating
4.04
4.19
Sensible capacity
Cooling
kW
4.05
5.30
Power factor
Cooling
%
98
98
Heating
98
96
Moisture removal
L/h (pints/h)
1.7 (3.0)
2.7 (4.8)
Maximum operating current *1
Cooling
A
9.5
13.5
Heating
13.5
16.0
Fan
Airflow rate
Cooling
HIGH
m
3
/h
980
1,170
MED
810
850
LOW
640
640
QUIET
510
510
Heating
HIGH
1,020
1,170
MED
850
850
LOW
640
640
QUIET
510
510
Type × Q'ty
Cross flow fan × 1
Motor output
W
59
Sound pressure level *2
Cooling
HIGH
dB (A)
45
49
MED
40
40
LOW
35
35
QUIET
29
29
Heating
HIGH
46
49
MED
40
40
LOW
35
35
QUIET
29
29
Heat exchanger type
Dimensions (H × W × D)
mm
Main1: 210 × 798 × 26.6, Main2: 135 × 798 × 20
Sub1: 84 × 798 × 13.3, Sub2: 84 × 798 × 13.3
Fin pitch
Main1: 1.2, Main2: 1.1
Sub1: 1.4, Sub2: 1.4
Rows × Stages
Main1: 2 × 10, Main2: 2 × 8
Sub1: 1 × 4, Sub2: 1 × 4
Pipe type
Copper
Fin type
Aluminum
Enclosure
Material
Polystyrene
Color
White
Approximate color of Munsell N 9.25/
Dimensions
(H × W × D)
Net
mm
280 × 980 × 240
Gross
322 × 1,078 × 346
Weight
Net
kg
13.0
Gross
18
Connection pipe
Size
Liquid
mm (in)
Ø 6.35 (Ø 1/4)
Gas
Ø 12.70 (Ø 1/2)
Method
Flare
Drain hose
Material
PP + HDPE
Size
mm
Ø 13.8 (I.D.), Ø 15.8 to Ø 16.7 (O.D.)
Operation range
Cooling
°C
18 to 32
%RH
80 or less
Heating
°C
16 to 30
Remote control
Wireless remote controller (Option: Wired remote controller, Mobile app*3 [FGLair
™
])
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
– Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
– Pipe length: 5 m, Height difference: 0 m. (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *1: Maximum operating current is the total current of the indoor unit and the outdoor unit.
• *2: Sound pressure level:
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
• *3: Available on Google Play
™
store or on App Store
®
. Optional WLAN adapter is also required. For details, refer to the setting manual.
- 2 -
1. Specifications
WALL MOUNTED
ASHG18, 24KMTA
WALL MOUNTED
ASHG18, 24KMTA