SERVIS IP-Serial
1p Converter
User's Guide
174
7
T
roubleshoot
ing
Advanced version only
7.2.1.5 Compact
Flash
test
This test confirms the operation of the local bus and the read/write function for data.
This is a test only for the advanced version. For the standard version, the following
is displayed and this test cannot be performed.
7.2.1.5.1
data compare test
An zero clear verification and a full verification in 0x00
→
0xFF
→
0xAA
→
0x55
order for a read/write test are performed for the CF card register areas. This is
repeated 10 times.
Example
The CF signal status for GPIO Port-D and CF request register status are
displayed.
When the CF card is inserted, turn the card on and start the test. Turn the card off
when the test is finished.
Compact Flash test
---------------------
1: data compare test
2: bus integrity test
3: return
select >
select >
1
Enter
Loputo Board !
Please set CF sub-board.
GPIO Port-D CF_INTRQ:0 CF_ACK:0 CF_STATUS:0
CF_REQ register CF_STATUS:0 CF_nBUSY:1 CF_START:0 CF_STOP:0
<< CF Card present. >>
CF Power ON
CF_REQ register CF_STATUS:0 CF_nBUSY:1 CF_START:0 CF_STOP:0
zero clear ... success.
write 0x0000 ... success.
write 0xFFFF ... success.
write 0xAAAA ... success.
write 0x5555 ... success.
.
.
.
zero clear ... success.
write 0x0000 ... success.
write 0xFFFF ... success.
write 0xAAAA ... success.
write 0x5555 ... success.
CF Power OFF
CF_REQ register CF_STATUS:0 CF_nBUSY:1 CF_START:0 CF_STOP:0
Содержание FX-3001SR
Страница 22: ...SERVIS IP Serial 1p Converter User s Guide 12 1 Setup MEMO ...
Страница 60: ...SERVIS IP Serial 1p Converter User s Guide 50 3 Function Details MEMO ...
Страница 104: ...SERVIS IP Serial 1p Converter User s Guide 94 Command Descriptions 4 MEMO ...
Страница 164: ...SERVIS IP Serial 1p Converter User s Guide 154 6 Specifications MEMO ...