Chapter 5 Maintaining Optional Products
5.2 Installing Drive Enclosures
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation-
Copyright 2013 FUJITSU LIMITED
P3AM-4842-12ENZ0
77
(2)
Attach the rack rails to the rack.
Use the two plates to fasten the rack rails to the front rack pillars. Use the four washers to fasten the
rack rails to the rear rack pillars.
The M5 screw positions for the rack rails are determined by the drive enclosure base line.
Insert the M5 screws in the 1st and 6th holes on the front rack pillars above the base line and in the
2nd and 5th holes on the rear rack pillars above the base line to fasten the rack rails.
(3)
Tighten the M4 screws of the rack rails that were slightly unscrewed in
Make sure to attach the rack rails and rack pillars so that they fit exactly together without any
space between them.
(Front rack pillars)
(Rear rack pillars)
Washers
M5 screws
M5 screws
Washers
M5 screws
Plate
M5 screws
Plate
Rack rail (for right side)
Rack rail (for left side)
Front of drive enclosure
Rear of drive enclosure
[Left]
6th position
(M5 screw)
[Left]
1st position
(M5 screw)
5th position
(M5 screw)
2nd position
(M5 screw)
2U
2U
Base line of
drive enclosure
Base line of
drive enclosure
Rack rails
Rack rails
[Right]
[Right]
6th position
(M5 screw)
1st position
(M5 screw)
5th position
(M5 screw)
2nd position
(M5 screw)