Appendix A Event Notification Message List
A.2 Message List
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation-
Copyright 2013 FUJITSU LIMITED
P3AM-4842-12ENZ0
150
04
F1
01
CM is disconnected.
These sense codes are notified when
"Parts Error" is enabled for Error Severity
Level in the event notification setting.
They are not notified during
maintenance operations.
04
F1
0B
CM memory is disconnected.
04
F1
0C
CM BUD is disconnected.
04
F1
0D
CM FAN is disconnected.
04
F1
10
CA is disconnected.
04
F1
11
CA Port is disconnected.
04
F1
17
CA SFP+ is disconnected.
04
F1
19
CA SFP+ is disconnected.
04
F1
1A
CA SFP is disconnected.
04
F1
1C
CA SFP+ is disconnected.
04
F1
1D
CA SFP+ is disconnected.
04
F1
1E
Copper CA SFP+ is disconnected.
04
F1
1F
CA SFP is disconnected due to an SFP type that cannot be
recognized.
04
F1
2A
CM QSFP is disconnected.
04
F1
80
3.5" HDD is disconnected.
These sense codes are notified when
"Disk Error" is enabled for Error Severity
Level in the event notification setting.
They are not notified during
maintenance operations.
04
F1
81
2.5" HDD is disconnected.
04
F1
84
3.5" SSD is disconnected.
04
F1
85
2.5" SSD is disconnected.
04
F1
88
Drive is disconnected because an error occurred during the
Write check of the disk patrol.
04
F1
90
IOM is disconnected.
These sense codes are notified when
"Parts Error" is enabled for Error Severity
Level in the event notification setting.
They are not notified during
maintenance operations.
04
F1
91
IOM Port is disconnected.
04
F1
9A
IOM QSFP is disconnected.
04
F1
D2
DPSU is disconnected.
04
F1
DA
CE or DE exhaust temperature error is detected.
This sense code is notified when
"Temperature Error" or "Parts Error" is
enabled for Error Severity Level in the
event notification setting.
This is not notified during maintenance
operations.
04
F1
DB
CE or DE intake temperature error (sensor failure) is
detected.
These sense codes are notified when
"Parts Error" is enabled for Error Severity
Level in the event notification setting.
They are not notified during
maintenance operations.
04
F2
02
CM DMA Port is disconnected.
04
F2
03
CM BIOS is disconnected.
04
F2
04
CM RTC is disconnected.
04
F2
05
CM NVRAM is disconnected.
04
F2
06
CM EXP is disconnected.
04
F2
08
CM DI Port is disconnected.
04
F2
09
CM EXP IN port is disconnected.
04
F2
0A
CM EXP Out port is disconnected.
04
F2
0E
CM NAND Controller is disconnected.
04
F2
0F
CM SCU is disconnected.
04
F2
11
CA port is disconnected.
04
F2
21
CM FPGA is disconnected.
04
F2
22
CM LAN Port is disconnected.
Sense code
Description
Remarks
SK