Appendix A Event Notification Message List
A.2 Message List
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation-
Copyright 2013 FUJITSU LIMITED
P3AM-4842-12ENZ0
138
J 80
SSuu
0
N
5
8000
uu
0
N
0
HDD 3.5 DE#
uu
-Disk#
n
(SAS
xxx
GB
yy
krpm
ccccccc
)
SlowDown <
pppppppppppp ssssssssssss rrrr tttttt
>
These messages are
notified when "Disk
Warning" is enabled
for Warning Level in
the event notification
setting.
They are not notified
during maintenance
operations.
Disk performance error in the HDD is detected.
SS
: Component subtype
uu
: DE-ID ("00" for a controller enclosure)
N
: Disk slot number (0 – b (hexadecimal))
n
: Disk slot number (0 – 11 (decimal))
xxx
: Disk capacity (GB/TB)
yy
: Disk speed
cc...
: Disk information (RAID level or hot spare
(Spare))
pp...
: Component number
ss...
: Serial number
rr...
: Version
tt...
: Data code
: Configuration code
J 81
SSuuNN
5
8000
uuNN
0
HDD 2.5 DE#
uu
-Disk#
nn
(SAS
xxx
GB
yy
krpm
ccccccc
) SMART <
pppppppppppp ssssssssssss rrrr
tttttt qq
>
SMART is reported from the HDD.
SS
: Component subtype
uu
: DE-ID ("00" for a controller enclosure)
NN
: Disk slot number (0 – 17 (hexadecimal))
nn
: Disk slot number (0 – 23 (decimal))
xxx
: Disk capacity (GB/TB)
yy
: Disk speed
cc...
: Disk information (RAID level or hot spare
(Spare))
pp...
: Component number
ss...
: Serial number
rr...
: Version
tt...
: Data code
: Configuration code
J 81
SSuuNN
5
8000
uuNN
0
HDD 2.5 DE#
uu
-Disk#
nn
(SAS
xxx
GB
yy
krpm
ccccccc
) Warning <
pppppppppppp ssssssssssss rrrr
tttttt qq
>
HDD error is detected.
SS
: Component subtype
uu
: DE-ID ("00" for a controller enclosure)
NN
: Disk slot number (0 – 17 (hexadecimal))
nn
: Disk slot number (0 – 23 (decimal))
xxx
: Disk capacity (GB/TB)
yy
: Disk speed
cc...
: Disk information (RAID level or hot spare
(Spare))
pp...
: Component number
ss...
: Serial number
rr...
: Version
tt...
: Data code
: Configuration code
Event type
code
SNMP Trap
Upper: Message
Remarks
Trap
No.
TrapItemID
(*1)
Lower: Description
Содержание Eternus DX80 S2
Страница 1: ...ETERNUS DX80 S2 DX90 S2 Disk storage system User s Guide Operation P3AM 4842 12ENZ0 ...
Страница 2: ...This page is intentionally left blank ...
Страница 186: ......