About the Human sensor
Details about detection with the human sensor

   The human sensor detects whether there are people in 

the room by looking for movement by people in the room.

   Example of sensitivity range:

When the installation height gets higher, the temperature 
sensitivity decreases.

 CAUTION

Do not place large objects near the human sensor. Also 
keep heating units outside the sensor’s detection area.

0.8m

8.8m

3.2m

Equal sensitivity 

range of tempera-

ture 

Ceiling height: 3.2 m

Detecting position: 0.8 m from 

fl

 oor 

surface

Auto saving operation may not work when the room 
temperature is very different from the temperature de

fi

 ned 

in temperature setting, such as when immediately after 
starting the operation.

 NOTES

   Since the human sensor detects infrared light given out 

by people, there may be cases where this detection is 
incorrect.

Situations in which the sensor will detect no people in 
the room, even when there is someone there

•  When the temperature is high and the difference with 

between people’s body temperature is small. 
(Such as during the summer when the temperature is 
30

˚

C or higher)

•  When there is someone in the room, but they do not move 

for a long period of time.

•  When someone is hidden behind a sofa, other furniture, 

glass, or in similar situations.

•  When someone is wearing extremely thick clothing and 

has their back facing the sensor.

Situations in which the sensor will incorrectly detect 
people in the room, even when there is no one there

•  When there is a dog or a cat moving around in the room.
•  When the wind is making curtains or plants move.
•   When there are heating units, humidi

fi

 ers, or electric ap-

pliances such as oscillating electric fans operating.

Economy operation

At the maximum outlet, ECONOMY operation is approxi-
mately 70 % of normal air conditioner operation for cooling 
and heating.
If the room is not cooled (or heated), well during ECONOMY 
operation, select normal operation.

Fan speed

Controls the fan speed.

AUTO

HIGH

QUIET

MED

LOW

When AUTO is selected, the fan speed is automatically ad-

justed according to the operation mode.

Heating*:   The fan will operate at very low speed when the tem-

perature of the air issued from the indoor unit is low.

Cooling:  

As the room temperature approaches that of the 

set temperature, the fan speed becomes slower.

Fan:  

The fan runs at medium fan speed.

Fan control for energy saving

•  At Cooling or Dry mode, by using this function, the indoor 

unit fan will operate intermittently at a very low speed when 

the outdoor unit is stopped.

•  When the fan setting is at Auto, this function will automati-

cally be active to prevent humidity from returning to the 

room. To use this function in other fan modes, refer to the 

operation manual of the remote controller.

* To use this function with other remote controllers, please 

consult an authorized service personnel.

Auto restart

In Event of Power Interruption

•  Should the power supply to the air conditioner be interrupted 

by a power failure, the air conditioner will restart automatically 

in the previously selected mode once the power is restored.

•  Use of other electrical appliances (electric shaver, etc.) or 

nearby use of a wireless radio transmitter may cause the 

air conditioner to malfunction. In this event, temporarily 

disconnect the power supply, reconnect it, and then use 

the remote controller to resume operation.

Multiple remote controller (optional)

An additional remote controller can be added up to the 

maximum of two remote controllers. Either remote controller 

can control the air conditioner. However, the timer functions 

cannot be used at the secondary unit.

Group control

One remote controller can control up to 16 air conditioners.

All of the air conditioners will be operated with the same settings.

Demand Response and Indoor Unit Operation

This product is designed to be compatible with Air Conditioning 

Demand Response program.

To utilize the function, you need a separate arrangement with your 

electricity supplier. Please check availability in the place of use.

When your electricity supplier activates one of the following 3 De-

mand Response (DR) modes, the air conditioner switches over to the 

appropriate operation. If the optional IR receiver is installed, operation 

indicators will inform you when the unit has entered the DR mode.

OPERATION indicator

Blinking pattern and the intervals are as follows

 AUTO/COOL/HEAT/DRY/FAN operations

ON (4 seconds)

OFF (0.5 seconds)

OFF (0.5 seconds)

ON (0.5 seconds)

 10

˚

C HEAT operation

OFF (4 seconds)

ON (0.5 seconds)

ON (0.5 seconds)

OFF (0.5 seconds)

 

The indicator will keep blinking until the unit finishes the 
function.

9381622016-03_OM_EN.indd   6

9381622016-03_OM_EN.indd   6

2015/11/26   15:26:17

2015/11/26   15:26:17

Содержание autg30krla

Страница 1: ...AIR CONDITIONER KEEP THIS MANUAL FOR FUTURE REFERENCE PART No 9381622016 03 Indoor Unit AUTG30KRLA AUTG36KRLA AUTG45KRLA AUTG54KRLA OPERATING MANUAL Cassette type ...

Страница 2: ... the electrical breaker or disconnecting the power plug Then consult authorized service personnel Take care not to damage the power supply cable If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and con sult authorized ...

Страница 3: ...onal ventilation during use Always operate this product with air filters installed Ensure that any electronic equipment is at least 1 m away from this product Turn off power source when not using this prod uct for extended periods After a long period of use ensure to get the mounting of the indoor unit checked to prevent this product from falling down The air flow direction and the room temperatur...

Страница 4: ...Use the DAY OFF setting to switch off timed operation for a selected day in the coming week Because all days can be set together the weekly timer can be used to repeat the timer settings for all of the days REMOVABLE INTAKE GRILLE The indoor unit s intake grille can be removed for easy clean ing and maintenance WIRED REMOTE CONTROLLER The wired remote controller allows convenient control of indoor...

Страница 5: ...start of heating operation during defrost or when AUTO auto changeover is selected NOTES Attempting to move up down air direction flaps manu ally could result in improper operation in this case stop operation and restart The louvers should begin to operate properly again When used in a room with infants children elderly or sick persons the air direction and room temperature should be considered ca...

Страница 6: ...humidifying your room You cannot heat the room during Dry mode During Dry mode the unit will operate at low speed in order to adjust room humidity the indoor unit s fan may stop from time to time Also the fan may operate at very low speed when adjusting room humidity The fan speed cannot be changed manually when Dry mode has been selected Fan Use to circulate the air throughout your room NOTES Dur...

Страница 7: ...Cooling As the room temperature approaches that of the set temperature the fan speed becomes slower Fan The fan runs at medium fan speed Fan control for energy saving At Cooling or Dry mode by using this function the indoor unit fan will operate intermittently at a very low speed when the outdoor unit is stopped When the fan setting is at Auto this function will automati cally be active to prevent...

Страница 8: ...rse Cycle WARNING In the event of a malfunction burning smell etc immediately stop operation turn off the electrical breaker and consult authorized service personnel Merely turning off the unit s power switch will not completely disconnect the unit from the power source Always be sure to turn off the electrical breaker to ensure that power is completely off Before requesting service perform the fo...

Страница 9: ...humidity set a lower room tempera ture CHECK ONCE MORE Does not operate at all Has the circuit breaker been turned off Has there been a power failure Has a fuse blown out or a circuit breaker been tripped Is the timer operating Is the Auto off operation of the Human sensor setting ac tive Poor cooling or heating performance Is the air filter dirty Are the air conditioner s intake grille or outlet ...

Страница 10: ......

Страница 11: ......

Страница 12: ......

Отзывы: